stress corrosion cracking detection of sensitized stainless steel 304 in chloride media by using electrochemical impedance spectroscopy (eis)
|
|
|
|
|
نویسنده
|
neshati j. ,adib b. ,sardashti a.
|
منبع
|
journal of petroleum science and technology - 2012 - دوره : 2 - شماره : 1 - صفحه:55 -60
|
چکیده
|
Electrochemical impedance spectroscopy (eis) was used to detect stress corrosion cracking (scc)in stainless steel 304 alloy exposed to an aqueous environment at 120 °c. stainless steel 304 alloyas u-bend was tested in the solution that contains 40 weight percent of magnesium chloride. ubendedsamples were prepared according to astm g30. eis measurements were always performedsimultaneously on u-bend samples under stress and non-stress conditions. the results indicate thatchanges in phase shift versus time could be related to the stress corrosion cracking process. stresscorrosion cracking is detectable at a frequency of 23.95 hz. eis measurement can be used for sccmonitoring in u-bend samples. finally, analysis of the fracture surface by using metallographic andsem techniques confirmed the eis results
|
کلیدواژه
|
stress corrosion cracking ,stainless steel 304 ,u-bend ,monitoring ,eis
|
آدرس
|
research institute of petroleum industry (ripi), corrosion department, iran, islamic azad university, north tehran branch, department of chemistry, iran, islamic azad university, north tehran branch, department of chemistry, iran
|
|
|
|
|
|
|
|
|
|
|
|
|
|