>
Fa   |   Ar   |   En
   dosimetric evaluation of the treatment plan on indigenous heterogeneous phantoms using analytical anisotropic algorithm and acuros-xb algorithm for different photon energies  
   
نویسنده gangwar vinod kumar ,gurjar om prakash ,kumar lalit ,agarwal avinash ,mishra vineet kumar ,prasad mishra surendra ,pandey saket
منبع journal of biomedical physics and engineering - 2022 - دوره : 12 - شماره : 3 - صفحه:237 -244
چکیده    Background: modern radiotherapy techniques are using advanced algorithms; however, phantoms used for quality assurance have homogeneous density; accordingly, the development of heterogeneous phantom mimicking human body sites is imperative to examine variation between planned and delivered doses. objective: this study aimed to analyze the accuracy of planned dose by different algorithms using indigenously developed heterogeneous thoracic phantom (ht). material and methods: in this experimental study, computed tomography (ct) of ht was done, and the density of different parts was measured. the plan was generated on ct images of hcp with 6 and 15 megavoltage (mv) photon beams using different treatment techniques, including three-dimensional conformal radiotherapy (3d-crt), intensity-modulated radiation therapy (imrt), and volumetric modulated arc therapy (vmat). plans were delivered by the linear accelerator, and the dose was measured using the ion chamber (ic) placed in ht; planned and measured doses were compared. results: density patterns for different parts of the fabricated phantom, including rib, spine, scapula, lung, chest wall, and heart were 1.849, 1.976, 1.983, 0.173, 0.855, and 0.833 g/cc, respectively. variation between planned and ic estimated doses with the tolerance (±5%) for all photon energies using different techniques. acuros-xb (axb) showed a slightly higher variation between computed and ic estimated doses using hcp compared to the analytical anisotropic algorithm (aaa). conclusion: the indigenous heterogeneous phantom can accurately simulate the dosimetric scenario for different algorithms (axb or aaa) and be also utilized for routine patient-specific qa.
کلیدواژه algorithms ,computed tomography ,human body ,lung phantoms ,volumetricmodulated arc therapy ,ribs
آدرس m.j.p. rohilkhand university, department of physics, india, mahatma gandhi memorial medical college, government cancer hospital, india, dr. a.p.j abdul kalam technical university, department of applied science & humanities, india, bareilly college, department of physics, india, apollomedics hospital, india, ram manohar lohia medical sciences lucknow, department of radiation oncology, india, apollomedics hospital, medical physics division & amp department of radiation oncology, india
پست الکترونیکی saketp25@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved