   determination of diagnostic reference level (drl) in common computed tomography examinations with the modified quality control-based dose survey method in four university centers: a comparison of methods  
   
نویسنده tabesh jalal ,mahdavi maziyar ,hadadi gholamhasan ,ravanfar haghighi rezvan ,jalli reza
منبع journal of biomedical physics and engineering - 2021 - دوره : 11 - شماره : 4 - صفحه:447 -458
چکیده    Background: the diagnostic reference level (drl) is measured with different methods in the common computed tomography (ct) exams, but it has not been measured through the sizespecific dose estimate (ssde) method in iran, yet.objective: this study aimed to calculate the local drl (ldrl) using the new quality control-based dose survey method (qc) and patients’ effective diameter (mqc) and compare them with a data collection method (dc) as well as local national drls (ndrl).material and methods: in this crosssectional study, ldrl, based on the third quartile of volumetric computed tomography dose index (ctdivol) and dose length product (dlp) values, was calculated for the four common ct examinations in four ct scan centers affiliated with shiraz university of medical sciences by dc, qc and mqc methods. the ctdivol of each patient for each ct exam calculated with three methods was compared with paired ttest. also, the ldrl using mqc method was compared with other national drl studies. results: there was a significant difference between the ctdivol values calculated with mqc and qc in all four examinations (p <0.001). the ldrl based on ctdivol obtained by the mqc method for head, sinus, chest, abdomen, and pelvis were (50, 18, 15, 19) mgy, respectively, and the calculated dlp values were also (735, 232, 519, 984) mgy.cm. conclusion: in mqc, ldrl based on ctdivol was calculated with a mean difference percentage of (19.2 ± 11.6)% and (27.1 ± 8.1)% as compared to the qc and dc methods, respectively. this difference resulted from the use of the ssde method and dose accuracy in the qc dose survey.
کلیدواژه diagnostic reference levels ,multidetector computed tomography ,quality control-based dose survey method ,size-specific dose estimate ,body mass index
آدرس shiraz university of medical sciences, school of paramedical sciences, department of radiology, iran, shiraz university of medical sciences, school of paramedical sciences, ionizing and non-ionizing radiation protection research center (inirprc), department of radiology, iran, shiraz university of medical sciences, school of paramedical sciences, ionizing and non-ionizing radiation protection research center (inirprc), department of radiology, iran, shiraz university of medical sciences, medical imaging research center, iran, shiraz university of medical sciences, medical imaging research center, iran
پست الکترونیکی jallireza@yahoo.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved