>
Fa   |   Ar   |   En
   finite element analysis of different hip implant designs along with femur under static loading conditions  
   
نویسنده chethan k n ,shyamasunder bhat n ,zuber m ,satish shenoy b
منبع journal of biomedical physics and engineering - 2019 - دوره : 9 - شماره : 5 - صفحه:507 -516
چکیده    Background: the hip joint is the largest joint after the knee, which gives stability to the whole human structure. the hip joint consists of a femoral head which articulates with the acetabulum. due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. since the early 19th century, the hip joint arthroplasty has evolved, and many advances have been taken in the field which improved the whole procedure. currently, there is a wide variety of implants available varying in the length of stem, shapes, and sizes. material and methods: in this analytical study of femur, circular, oval, ellipse and trapezoidalshaped stem designs are considered in the present study. the human femur is modeled using mimics. catia v6 is used to model the implant models. static structural analysis is carried out using ansys r19 to evaluate the best implant design. results: all the four hip implants exhibited the von mises stresses, lesser than its yielded strength. however, circular and trapezoidalshaped stems have less von mises stress compared to ellipse and oval. conclusion: this study shows the behavior of different implant designs when their crosssections are varied. further, these implants can be considered for dynamic analysis considering different gait cycles. by optimizing the implant design, life expectancy of the implant can be improved, which will avoid the revision of the hip implant in active adult patients.
کلیدواژه von mises stress ,hip prosthesis ,finite element analysis ,static analysis ,total deformation ,femur
آدرس manipal academy of higher education, manipal institute of technology, department of aeronautical and automobile engineering, india, manipal academy of higher education, kasturba medical college, department of orthopedics, india, manipal academy of higher education, manipal institute of technology, department of aeronautical and automobile engineering, india, manipal academy of higher education, manipal institute of technology, department of aeronautical and automobile engineering, india
پست الکترونیکی satishshenoy@manipal.edu
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved