   dosimetry of critical organs in maxillofacial imaging with cone-beam computed tomography  
   
نویسنده ghanbarnezhad farshi r ,mesbahi a ,johari m ,kara ü ,gharehaghaji n
منبع journal of biomedical physics and engineering - 2019 - دوره : 9 - شماره : 1 - صفحه:51 -60
چکیده    Background: while the benefits of conebeam computed tomography (cbct) are well known in maxillofacial imaging, the use of this modality is not riskfree.objective: the aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with cbct.methods: entrance surface dose (esd) was measured by using thermoluminescent dosimeters (tlds) attached to the eyes lids, parotid glands and thyroid of 64 patients in two imaging centers (a and b). phantom dosimetry was performed by a cylindrical polymethyl methacrylate (pmma) headsize phantom and an ionization chamber for different exposure parameters. newtom vgi and planmeca promax 3d cbct scanners were used at centers a and b, respectively.results: the mean esd of the eyes, parotid glands and thyroid were 2.57, 2.33 and 0.28 mgy in center a, 0.35, 2.11 and 0.37 mgy in center b, respectively. esd of the eyes revealed a significant difference in two centers; in center b, it was 86.4% lower than center a. in the phantom dosimetry, the measured doses of newtom vgi were 2.63 and 2.08 mgy, respectively by changing field of view (fov) size from 8×8 cm^2 (height × diameter) to 6×6 cm^2. for planmeca promax 3d, it ranged from 0.98 to 3.24 mgy depending on exposure parameters.conclusion: there is a wide range of radiation doses dependent on the units, patients and selected scan parameters. inappropriate selection of exposure settings, especially fov size, can seriously increase patient dose.
کلیدواژه conebeam computed tomography ,radiation dosimetry ,entrance surface dose ,thermoluminescent dosimetry ,maxillofacial imaging ,dentistry
آدرس tabriz university of medical sciences, immunology research center, faculty of medicine, iran|medical physics department, iran, tabriz university of medical sciences, faculty of medicine, medical physics department, iran, tabriz university of medical sciences, faculty of dentistry, department of oral & maxillofacial radiology, iran, suleyman demirel university, vocational school of health services, turkey, tabriz university of medical sciences, paramedical faculty, radiology department, iran
پست الکترونیکی gharehaghaji@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved