Fa   |   Ar   |   En
   evaluation of lung density and its dosimetric impact on lung cancer radiotherapy: a simulation study  
   
نویسنده raj verma t ,kumar painuly n ,prasad mishra s ,yoganathan s a ,singh n ,bhatt m l b ,jamal n
منبع journal of biomedical physics and engineering - 2019 - دوره : 9 - شماره : 1 - صفحه:17 -28
چکیده    Background: the dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. therefore, it becomes necessary to quantify these deviations.objective: the present study has been undertaken to find out inter and intra lung density variations and its dosimetric impact on lung cancer radiotherapy using monte carlo code fluka and pbc algorithms.material and methods: density of 100 lungs was recorded from their ct images along with age. then, after pdd calculated by fluka mc code and pbc algorithm for virtual phantom having density 0.2 gm/cm3 and 0.4 gm/cm3 (density range obtained from ct images of 100 lungs) using co60 10 x10 cm2 beams were compared.results: average left and right lung densities were 0.275±0.387 and 0.270±0.383 respectively. the deviation in pbc calculated pdd were (+)216%, (+91%), (+)45%, (+)26.88%, (+)14%, ()1%, (+)2%, ()0.4%, ()1%, (+)1%, (+)4%, (+)4.5% for 0.4 gm/cm3 and (+)311%, (+)177%, (+)118%, (+)90.95%, (+)72.23%, (+)55.83% ,(+)38.85%, (+)28.80%, (+)21.79%, (+)15.95%, (+)1.67%, () 2.13%, (+)1.27%, (+)0.35%, ()1.79%, ()2.75% for 0.2 gm/cm3 density mediums at depths of 1mm, 2mm, 3mm, 4mm, 5mm, 6 mm, 7 mm, 8mm, 9mm,10mm, 15mm, 30mm, 40mm, 50mm, 80mm and 100 mm, respectively.conclusion: large variations in inter and intra lung density were recorded. pbc overestimated the dose at air/lung interface as well as inside lung. the results of monte carlo simulation can be used to assess the performance of other treatment planning systems used in lung cancer radiotherapy.
کلیدواژه pbc ,monte carlo code fluka ,variation in lung density ,virtual phantom ,computed tomography
آدرس king george medical university, iran, king george medical university, iran, dr.ram manohar lohia institute of medical sciences, iran, sanjay gandhi post graduate institute of medical sciences, iran, king george medical university, iran, king george medical university, iran, king george medical university, iran
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved