a monte carlo study on dose enhancement by homogeneous and inhomogeneous distributions of gold nanoparticles in radiotherapy with low energy x-rays
|
|
|
|
|
|
|
|
نویسنده
|
zabihzadeh m ,moshirian t ,ghorbani m ,knaup c ,behrooz m a
|
|
منبع
|
journal of biomedical physics and engineering - 2018 - دوره : 8 - شماره : 1 - صفحه:13 -28
|
|
چکیده
|
Background: to enhance the dose to tumor, the use of high atomic number elements has been proposed.objective:the aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in tumor when the tumor is irradiated by typical monoenergetic x-ray beams by considering homogeneous and inhomogeneous distributions of gold nanoparticles (gnps) in the tumor.methods:mcnp-4c monte carlo code was utilized for the simulation of a source, a phantom containing tumor and gold nanoparticles with concentrations of 10, 30 and 70 mg au/g tumor. a 15 cm×15 cm×15 cm cubic water phantom was irradiated with a small planar source with four monoenergetic x-ray beams of 35, 55, 75 and 95 kev energy. furthermore, tumor depths of 2.5 cm, 4.5 cm and 6.5 cm with homogeneous and inhomogeneous distributions of nanoparticles were studied. each concentration, photon energy, tumor depth and type of distribution was evaluated in a separate simulation.results:results have shown that dose enhancement factor (def) in tumor in-creases approximately linearly with the concentration of gold nanoparticles. while def has fluctuations with photon energy, 55 kev photons have the highest def values compared to other energies. while def has relatively the same values with tumor located at various depths, inhomogeneous distribution of gnp has shown different results compared with the homogeneous model. dose enhancement can be expected with relatively deep seated tumors in radiotherapy with low energy x-rays. inhomogeneous model is recommended for the purpose of dose enhancement study because it mimics the real distribution of gnps in tumor.
|
|
کلیدواژه
|
gold nanoparticle ,dose enhancement ,homogeneous distribution ,inhomogeneous distribution ,monte carlo simulation
|
|
آدرس
|
ahvaz jundishapur university of medical sciences, faculty of medicine, golestan hospital, student research committee, department of medical physics, department of clinical oncology, iran, ahvaz jundishapur university of medical sciences, faculty of medicine, department of medical physics, iran, shahid beheshti university of medical sciences, faculty of medicine, biomedical engineering and medical physics department, iran, comprehensive cancer centers of nevada, usa, ahvaz jundishapur university of medical sciences, faculty of medicine, department of medical physics, iran
|
|
پست الکترونیکی
|
behrooz_m@aums.ac.ir
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|