|
|
|
|
simultaneous screening of nitrofuran metabolites in honey using biochip array technology: validation study according to the decision 2002/657/ec of the european union
|
|
|
|
|
|
|
|
نویسنده
|
yazdanpanah hassan ,osouli mahraz ,salamzadeh jamshid ,karimi zakieh ,rashidi elham ,borhan ali ,yazdanpanah alireza ,eslamizad samira
|
|
منبع
|
iranian journal of pharmaceutical research - 2022 - دوره : 21 - شماره : 1 - صفحه:1 -9
|
|
چکیده
|
Background: although no authorization is available for antibiotics to treat bee diseases, some veterinary compounds are used by beekeepers, and each country sets its own thresholds. inappropriate and excessive use of these drugs can cause allergic reactions and antibiotic resistance in humans who consume the remaining antibiotic residues in honey and its products. it is, therefore, relevant to monitor the presence of antibiotic residues in this matrix. objectives: a rapid method for the simultaneous screening of nitrofuran metabolite residues in honey was validated according to commission decision 2002/657/ec (c.d 657) and the european guideline for the validation of screening methods for veterinary medicines. methods: this multi-analytical screening method enables the simultaneous determination of four nitrofuran metabolites [3-amino-2-oxazolidone (aoz), 3-amino-5-morpholinomethyl-2-oxazolidinone (amoz), 1-aminohydantoin hcl (adh), and semicarbazide (sec)] from a single honey sample. thirty-five honey samples were collected randomly as real samples for screening from tehran, ir iran, germany, and the netherlands in 2018. results: for all four antibiotic residues, the positivity threshold t was higher than the cut-off value fm, and no false-positive results were obtained for three antibiotics (aoz, amoz, and sec). detection capabilities (ccβ) of all compounds were under the minimum required performance limit (mrpl) authorized by the european commission (currently 1 μg/kg). the screening results of 15 domestic and 20 imported honey samples showed that the levels of aoz in 6.66% and 10% of the samples, the level of amoz in 13.33% and 0% of the samples, and the level of sec in 33.33% and 40% of the samples were less than the cut-off ([in relative light units (rlus)], respectively. conclusions: this study found that this technique is valid for detecting and quantifying three antibiotic residues in honey samples at the measured validation levels. this method was simple, rapid, and capable of simultaneously screening three nitrofuran metabolites from a single honey sample.
|
|
کلیدواژه
|
nitrofuran ,honey ,nanoarray analytical device ,validation study
|
|
آدرس
|
shahid beheshti university of medical sciences, school of pharmacy, food safety research center, department of toxicology and pharmacology, iran, shahid beheshti university of medical sciences, food safety research center, iran, shahid beheshti university of medical sciences, food safety research center, iran, shahid beheshti university of medical sciences, food safety research center, iran, shahid beheshti university of medical sciences, food safety research center, iran, shahid beheshti university of medical sciences, school of pharmacy, department of pharmaceutics, iran, islamic azad university, tehran medical sciences, faculty of pharmacy, medicinal chemistry department, iran, shahid beheshti university of medical sciences, food safety research center, iran
|
|
پست الکترونیکی
|
s.eslami@sbmu.ac.ir
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|