   comparison of body composition assessed by multi-frequency segmental bioelectrical impedance analysis and dual energy x-ray absorptiometry in hemodialysis patients  
   
نویسنده najafi mohammad taghi ,nasiri omid ,alamdari azam ,minoo farzanehsadat ,abbasi mehrshad ,farzanefar saeed ,abbasi mohammad reza
منبع nephro-urology monthly - 2018 - دوره : 10 - شماره : 6 - صفحه:1 -5
چکیده    Background:the assessment of body composition during the course of treatment of hemodialysis patients is crucial for optimal treatment. we intended to assess the diagnostic performance of bioelectrical impedance analysis (bia), which could be used at the bedside in dialysis wards, and compare it with the results of dualenergy xray absorptiometry (dexa).methods:in a crosssectional study, 43 patients with endstage renal disease (esrd) after hemodialysis sessions underwent direct segmental multifrequency bia. volume status and body composition indices with eight electrodes connected to four limbs were measured at 1, 5, 50, 250, 500, and 1000 khz frequencies. then, the patients were sent to the nuclear ward for the corresponding assessments by dexa. the results of the two methods were compared by a paired <i>t</i>test and the correlations were assessed using general linear models and regression analyses. for the assessment of agreements, baldaltman plots were used.results:the whole body values for bone, fat, and lean body mass were different between bia (3.4, 22, and 44.5 kg, respectively) and dexa (1.5, 28.5, and 40.4 kg, respectively). however, the results were strongly linearly correlated even after adjustment for age and sex (r = 0.67, p = 0.001 for bone mass; r = 0.93, p = 0.001 for fat mass; and r = 0.96, p = 0.001 for lean body mass). the same strong correlation was found for the segmental values.conclusions:the results of bia and dexa are correlated strongly and are interchangeable. as the bia is more easily available and less expensive, the routine use of bia at hemodialysis departments is reasonable.
کلیدواژه dual-energy x-ray absorptiometry (dexa) ,bioelectrical impedance analysis (bia) ,hemodialysis ,body composition ,fat mass ,bone mass ,lean body mass
آدرس tehran university of medical sciences, nephrology research center, iran, tehran university of medical sciences, nephrology research center, iran, tehran university of medical sciences, nephrology research center, iran, tehran university of medical sciences, nephrology research center, iran, tehran university of medical sciences, vali-asr hospital, department of nuclear medicine, iran, tehran university of medical sciences, vali-asr hospital, department of nuclear medicine, iran, tehran university of medical sciences, nephrology research center, iran
پست الکترونیکی abbasi45mzh@yahoo.com
 
     
   