The Value of Changing Position in the Detection of CSF Leakage in Spontaneous Intracranial Hypotension Using Tc-99m DTPA Scintigraphy: Two Case Reports
|
|
|
|
|
|
|
|
نویسنده
|
Lu Yu-Yu ,Wang Hsin-Yi ,Lin Ying ,Lin Wan-Yu
|
|
منبع
|
iranian journal of radiology - 2012 - دوره : 9 - شماره : 3 - صفحه:150 -153
|
|
چکیده
|
Radionuclide cisternography (rnc) is of potential value in pointing out the sites of cerebrospinal fluid (csf) leakage in patients with spontaneous intracranial hypotension (sih). in the current report, we present two patients who underwent rnc for suspected csf leakage. both patients underwent magnetic resonance imaging (mri) and rnc for evaluation. we describe a simple method to increase the detection ability of rnc for csf leakage in patients with sih.
|
|
کلیدواژه
|
Intracranial Hypotension- Technetium- Magnetic Resonance Imaging- Scintigraphy
|
|
آدرس
|
Taichung Veterans General Hospital, Department of Nuclear Medicine, Taiwan, Taichung Veterans General Hospital, Department of Nuclear Medicine, Taiwan, Taichung Veterans General Hospital, Department of Nuclear Medicine, Taiwan, Taichung Veterans General Hospital, Department of Nuclear Medicine, Taiwan
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|