>
Fa   |   Ar   |   En
   intra- and inter-rater reliability of a magnetic resonance imaging-based volumetric analysis of the abductor hallucis muscle  
   
نویسنده jalali maryam ,moulodi nasrin ,azadinia fatemeh ,shakourirad ali ,sarrafzadeh javad
منبع iranian journal of radiology - 2022 - دوره : 19 - شماره : 3 - صفحه:1 -8
چکیده    Background: the muscle volume considerably changes with aging, pathologies, mechanical loading and exercise, and immobilization. it is recognized as an important parameter that can be measured by various methods to evaluate the effectiveness of interventions focusing on muscle strengthening and function. however, before the application of any measurement method, their reliability needs to be investigated and established. objectives: this study aimed to evaluate the inter- and intra-rater reliability of the manual measurement method of the abductor hallucis muscle volume in feet with hallux valgus deformities using magnetic resonance imaging (mri). patients and methods: the mri images of the feet of 15 samples with a hallux valgus deformity were selected in this study. the cross-sectional areas of the abductor hallucis muscle were measured in the cuts along the entire length of the foot and multiplied by slice thickness. two trained raters performed the measurements. the second rater repeated the measurements after five days to eliminate the memory effect. the intra-rater reliability and inter-rater reliability were assessed based on the intraclass correlation coefficient [icc (2, 1)] to evaluate the extent of agreement between the raters at a 95% confidence interval. results: the between- and within-rater iccs were 0.92 (0.79 - 0.97) and 0.99 (0.97 - 0.99), respectively. the standard error of measurements was also small in both inter-rater (6.2%) and intra-rater (2.1%) reliability analyses. conclusion: the manually outlined slice-by-slice volume measurement of the abductor hallucis muscle based on mri images showed excellent inter- and intra-rater reliability. the excellent intra-rater reliability, besides the lower standard error percentage of measurements, indicates the superiority of measurements by a single person. however, further studies with a larger sample size are recommended.
کلیدواژه magnetic resonance imaging ,muscle volume ,reliability ,abductor hallucis muscle ,hallux valgus
آدرس iran university of medical sciences, rehabilitation research center, school of rehabilitation sciences, department of orthotics and prosthetics, iran, iran university of medical sciences, rehabilitation research center, school of rehabilitation sciences, student research committee, department of orthotics and prosthetics, iran, iran university of medical sciences, rehabilitation research center, school of rehabilitation sciences, department of orthotics and prosthetics, iran, tehran university of medical sciences, sina hospital, department of radiology, iran, iran university of medical sciences, rehabilitation research center, school of rehabilitation sciences, department of physiotherapy, iran
پست الکترونیکی j.sarrafzadeh@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved