Fa   |   Ar   |   En
   evaluation of the patient effective dose in whole spine scanography based on the automatic image pasting method for digital radiography  
   
نویسنده kim jung-su ,yoon sang-wook ,seo deok-nam ,nam so-ra ,kim jung-min
منبع iranian journal of radiology - 2016 - دوره : 13 - شماره : 1 - صفحه:1 -7
چکیده    Background: whole spine scanography (wss) is a radiologic examination that requires whole body x-ray exposure. consequently, the amount of patient radiation exposure is higher than the radiation dose following routine x-ray examination. objectives: several studies have evaluated the patient effective dose (ed) following single exposure film-screen wss. the objective of this study was to evaluate patient ed during wss, based on the automatic image pasting method for multiple exposure digital radiography (apmdr). further, the calculated eds were compared with the results of previous studies involving single exposure film-screen wss. patients and methods: we evaluated the ed of 50 consecutive patients (m:f = 28:22) who underwent wss using apmdr. the anterior- posterior (ap) and lateral (lat) projection eds were evaluated based on the monte carlo simulation.results: using apmdr, the mean number of exposures was 6.1 for ap and 6.5 for lat projections. lat projections required more exposures (6.55%) than ap projections. the mean ed was 0.6276 msv (ap) and 0.6716 msv (lat). the mean ed for lat projections was 0.6061 msv in automatic exposure control (aec) and 0.7694 msv in manual mode. the relationship between dose-area-product (dap) and ed revealed a proportional correlation (ap, r^2 = 0.943; lat, r^2 = 0.773). compared to prior research involving single exposure screen-film wss, the patiented following wss using apmdr was lower on ap than on lat projections. conclusion: despite multiple exposures, ed control is more effective if wss is performed using apmdr in the aec mode.
کلیدواژه x-rays ,radiation dosage ,health physics
آدرس korea university, college of health science, department of radiologic science, south korea, cha university, cha bundang medical center, department of diagnostic radiology, south korea, korea university, college of health science, department of radiologic science, south korea, korea university, college of health science, department of radiologic science, south korea, korea university, college of health science, department of radiologic science, south korea
پست الکترونیکی minbogun@korea.ac.kr
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center