the use of polyvinyl chloride films dyed with methyl red in radiation dosimetry
|
|
|
|
|
|
|
|
نویسنده
|
kattan m. ,daher y.
|
|
منبع
|
international journal of radiation research - 2016 - دوره : 14 - شماره : 3 - صفحه:263 -267
|
|
چکیده
|
Background: the purpose of this work was to investigate the use of polyvinyl chloride (pvc) dyed with methyl red as a high dose radiation dosimetry. materials and methods: commercial pvc films from sabic made from resins pvc57s with thickness of 60 µm and methyl red with a molecular weight of 269.31 were used. irradiation was carried out using a^60co γ-ray generator with sources arranged in rectangular holder with a total activity of 73.6926 kci. absorbance measurements were made by jasco v- 630 uv-vis spectrophotometer. dose rate and irradiation temperature effects as well as postirradiation storage in dark and indirect daylight conditions on dosimetry performance were also investigated. results: the results showed a linear relationship between the relative absorbance (response) and the absorbed dose at the wavelength 548 nm in the range of 0-150 kgy. the response was found to be independent of both dose rate and irradiation temperature. conclusion: the experimental results indicate that pvc films dyed with methyl red may be used for a high dose radiation dosimetry.
|
|
کلیدواژه
|
polyvinyl chloride ,gamma radiation ,methyl red ,dosimetry.
|
|
آدرس
|
atomic energy commission of syria, department of radiation technology, accuracy of measurements division, syria, atomic energy commission of syria, department of radiation technology, accuracy of measurements division, syria
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|