   a novel phantom design for brachytherapy quality assurance  
   
نویسنده gholami s. ,mirzaei h.r. ,jabbary arfaee a. ,jaberi r. ,nedaie h.a. ,rabi mahdavi s. ,rajab bolookat e. ,meigooni a.s.
منبع international journal of radiation research - 2016 - دوره : 14 - شماره : 1 - صفحه:67 -71
چکیده    Background: one major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. in this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (gyn) brachytherapy implants using ebt gafchromic film. materials and methods: this phantom has been designed and fabricated from 90 slabs of 18times;16times;0.2 cm3 perspex to accommodate a tandem and ovoids assembly, which is normally used for gyn brachytherapy treatment. in addition, this phantom design is allowing the use ebt gafchromic films for dosimetric verification of gyn implants with cs137 selectron ldr system. with this assembly, gafchromic films were exposed using a plan designed to deliver 2.5 gy dose to point quot;aquot; in manchester system for tandem and ovoids configurations and to deliver 1.5 gy of dose to 0.5 cm distance from the lateral surface of ovoids for using ovoidpair. the measured dose distributions with gafchromic films were compared with the tps isodose lines both numerically and spatially. for a quantitative analysis of the results, the measured doses values at several points of interest were evaluated with the treatment planning data and values obtained following the tg43 dose calculation formalism. results: the results of these investigations have indicated that the new phantom design enables us to measure differences of greater than plusmn;6% for ldr brachytherapy gyn treatments. conclusion: the new phantom design could be utilized for the qa procedure of the brachytherapy remote after loading systems to confirm the accuracy of dose distribution in gyn implants.
کلیدواژه qa brachytherapy phantom ,film dose measurements ,selectron ldr system ,tg-43
آدرس tehran university of medical sciences tums, faculty of medicine, department of medical physics and biomedical engineering, ایران, shahid beheshti university of medical sciences, shohada e tajrish hospital, cancer research center, radiation oncology department, ایران, shahid beheshti university of medical sciences, shohada e tajrish hospital, cancer research center, radiation oncology department, ایران, tehran university of medical sciences tums, cancer institute, radiation oncology department, ایران, tehran university of medical sciences tums, cancer institute, faculty of medicine, radiation oncology department, department of medical physics and biomedical engineering, ایران, iran university of medical sciences, department of medical physics, ایران, shahid beheshti university of medical sciences, shohada e tajrish hospital, cancer research center, radiation oncology department, ایران, comprehensive cancer centers of nevada, usa
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved