|
|
|
|
Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations
|
|
|
|
|
|
|
|
نویسنده
|
Mesbahi A.
|
|
منبع
|
international journal of radiation research - 2008 - دوره : 5 - شماره : 4 - صفحه:181 -186
|
|
چکیده
|
Background: the monte carlo (mc) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (tps) calculations. materials and methods: three 60co sources of gzp6 brachytherapy unit were simulated using mcnp4c mc code. the radial dose functions were calculated by mc method and gzp6 tps and were compared. results: there was a good agreement between mc and tps calculations for all sources. discrepancies up to 10% were observed for points close to the sources, but for those farther than 7mm from source center, differences were less than 2% for all sources. conclusion: our results showed that gzp6 tps calculations can accurately be used for dose calculations in brachytherapy treatments for points farther than 7mm from the source center.
|
|
کلیدواژه
|
Brachytherapy ,high dose rate (HDR) ,60Co ,Monte Carlo
|
|
آدرس
|
tabriz university of medical sciences, Medical School, Imam-Khomeini Hospital, Medical Physics Department, Radiation Oncology Department, ایران
|
|
پست الکترونیکی
|
asgharmesbahi@yahoo.com
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|