Fa   |   Ar   |   En
   Passive neutron area monitor with CR39  
   
نویسنده Vega-Carrillo H.R. ,Barquero R. ,Mercado G.A.
منبع international journal of radiation research - 2013 - دوره : 11 - شماره : 3 - صفحه:149 -153
چکیده    Background: in high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless; in these conditions neutron measuring devices must have a passive detector. here a passive neutron area monitor with cr39 track detector was designed and the response was calculated. materials and methods: the response of a passive neutron area monitor with cr39 track detector has been calculated with the mcnpx code. to increase the detection efficiency a 10b converter was included. the response was calculated using 47 monoenergetic neutron sources. results: a passive neutron area monitor using a cr39 with 10b converter was designed where fluence and h*(10) responses were calculated. conclusion: the shape of the responses is similar to responses reported for neutron monitors with active detectors.
کلیدواژه Neutron dosimetry ,passive detector ,CR-39 ,Monte Carlo ,response.
آدرس Universidad Autonoma de Zacatecas, Unidad Académica de Estudios Nucleares, Mexico, Hospital Universitario Rio Hortega, Departamento de Radiología, Spain, Universidad Autónoma de Zacatecas, Unidad Academica de Matematicas, Mexico
 
     
   