   Assessment of image quality of two cone-beam computed tomography of the Varian Linear accelerators: Comparison with spiral CT simulator  
   
نویسنده ragab h. ,abdelaziz d.m. ,khalil m.m. ,elbakry m.n. yasein
منبع international journal of radiation research - 2023 - دوره : 21 - شماره : 3 - صفحه:491 -497
چکیده    Background: to assess and compare image quality characteristics of x-ray computed tomography (ct) and cone beam (cbct) imaging systems of the varian linear accelerator. materials and methods: the catphan®504, was examined on the ct simulator (somatom definition as, va48a) and two cbcts (truebeam™ and clinac® ix linear accelerators) attached to varian linear accelerator. image quality parameters including pixel value stability, spatial linearity, pixel size verification, uniformity, noise, spatial resolution, low contrast resolution, and contrast-to-noise ratio (cnr) were assessed using different scanning protocols. results: the mean pixel values of regions of interest were stable for ct, tb, and ix-cbct imaging. noise on ct was slightly lower and was seen to decrease with increasing mas, while cnr increased with ct mas and two cbcts. for all schemes, the modulation transfer function (mtf) of the reconstructed image was limited by the pixel size. low contrast targets for tb-cbct were visible, with up to 6 and 2 targets for 1% and 0.5% for contrast, respectively. however, up to 4 targets of 1% contrast on ix-cbct images are visible for the lowcontrast objectives. also, up to 8, 4, and 1 targets of 1%, 0.5%, and 0.3% contrast were visible for the low-contrast targets on ct images. conclusions: ct and cbct image quality parameters have been quantified and compared for clinical protocols in different mas conditions. selecting the right protocol will boost contrast, based on image quality criteria. the mas can be decreased to minimize patient dosage.
کلیدواژه Cone-beam computed tomography ,image quality ,TB-CBCT ,iX-CBCT
آدرس university of warith al. anbiyaa, warith international cancer institute (wici), department of radiation oncology, Iraq. baheya hospital for early detection and treatment of breast cancer, department of radiation oncology, Egypt, baheya hospital for early detection and treatment of breast cancer, department of radiation oncology, Egypt. cairo university, national cancer institute (nci), department of radiation oncology, Egypt, helwan university, faculty of science, department of physics, Egypt, helwan university, faculty of science, department of physics, Egypt
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved