Fa   |   Ar   |   En
   Estimating the radiation surface dose and measuring the dose area product to provide the diagnostic reference level in panoramic radiography  
   
نویسنده zamani h. ,parach a.a. ,razavi s.h. ,shabani m. ,ataei gh. ,zare m.h.
منبع international journal of radiation research - 2021 - دوره : 19 - شماره : 4 - صفحه:963 -970
چکیده    Background: panoramic radiography is one of the common dental imaging procedures using ionizing radiation. it is necessary to control the level of exposure and use the optimized levels. so, the current work aimed to estimate the surface absorbed doses of critical organ regions, namely thyroid and parotid glands. moreover, dose area product (dap) values were measured and a local drl was then established for panoramic radiography. materials and methods: the data from 201 patients including 141 adults and 60 children (5-10 years) were used for this cross-sectional study. seven panoramic radiography systems were selected from 6 radiology clinics in yazd province. for each patient, 12 thermoluminescence dosimeters (tld gr-200) were used to obtain the surface absorbed dose in both the thyroid and parotid gland regions. the drl values were calculated using dap values in terms of the icrp recommendation. results: the mean and standard deviation (sd) of thyroid and parotid glands’ surface absorbed doses were equal to 60.6±3.7 and 290±12.4 μgy in the adult group, respectively. in the children group, these values were 40.7±2 and 189.3±11.5 μgy, respectively. moreover, the local drl values were obtained as 99.7 and 73.4 mgy.cm2 for the adults and children groups, respectively. conclusion: the higher surface absorbed dose values in the adult group can be related to the use of higher radiation parameters. the local drl proposed for the adult and pediatric groups in the current study was relatively lower than those established by other reports, which seemed acceptable for panoramic radiography in yazd, iran.
کلیدواژه Panoramic radiography ,surface dose ,dose area aroduct ,diagnostic reference level
آدرس shahid sadoughi university of medical sciences, department of medical physics, Iran, shahid sadoughi university of medical sciences, department of medical physics, Iran, shahid sadoughi university of medical sciences, faculty of density, department of oral and maxillofacial radiology, Iran, shahid sadoughi university of medical sciences, radiotherapy research center, Iran, babol university of medical science, faculty of paramedical sciences, department of radiology technology, iran, shahid sadoughi university of medical sciences, department of medical physics, Iran
پست الکترونیکی mhzare2009@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center