>
Fa   |   Ar   |   En
   Uncertainties in effective dose estimation for CT transmission scan in total body PET-CT imaging with Auto mA3D tube current modulation  
   
نویسنده salimi y. ,deevband m.r. ,ghafarian p. ,ay m.r.
منبع international journal of radiation research - 2018 - دوره : 16 - شماره : 4 - صفحه:465 -472
چکیده    Background: positron emission tomography-computed tomography (pet-ct) is auseful hybrid imaging modality in the diagnosis of various malignancies. thismodality imposes almost 20 msv radiation dose to the patient. the purpose of thepresent study was to evaluate the uncertainties in calculated ct effective dose intube current modulation-activated scans by impact-dose software. materialsand methods: sixty total body dicom (30 male and 30 female) whole body pet-ctimages were selected. volume ct dose index (ctdivol) was recorded for each ofthe procedures. the image was divided into 5 regions of head & neck, chest,abdomen, pelvis and lower limbs according to special anatomical markers. effectivedoses for total body and separate organs were calculated by means of impact-dosesoftware once with global ctdivol and once with a summation of doses calculatedby 5 regional ctdivol and related scan ranges. results: the difference amongeffective doses for some organs and total body were considerable. the meanand standard deviation (sd) of the coefficient of variations (cv%) for totalbody, breast, gonads, liver, lung, red bone marrow (rbm), thyroid, kidneys,and uterus were 12.56, 11.61, 9.44, 8.1, 11.31, 5.93, 8.61, 6.03 and 12.49,respectively. uncertainties were higher for smaller patients by 19 noiseindexes while these changes were higher for bigger patients and 22 noiseindexes. conclusion: the tube current variation depends on the acquisition andpatient parameters. for measuring and reporting the total body and organs’effective doses in order to estimate the risks of ct’s radiation for total body pet-ctprocedures, the tube current variations must be considered.
کلیدواژه Effective dose ,computed tomography ,individual dosimetry ,PET-CT ,regional CTDI
آدرس shahid beheshti university of medical sciences, department of medical engineering and physics, Iran, shahid beheshti university of medical sciences, department of medical engineering and physics, Iran, shahid beheshti university of medical sciences, chronic respiratory diseases research center, national research institute of tuberculosis and lung diseases (nritld), pet/ct and cyclotron center of masih daneshvari hospital, Iran, tehran university of medical sciences, research center for molecular and cellular imaging, department of medical physics and biomedical engineering, Iran
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved