Determination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
|
|
|
|
|
|
|
|
نویسنده
|
tungjai m. ,phathakanon n. ,ketnuam p. ,tinlapat j.
|
|
منبع
|
international journal of radiation research - 2018 - دوره : 16 - شماره : 1 - صفحه:123 -127
|
|
چکیده
|
Background: people occasionally undergo medical diagnostic x-ray examinationsand expose their red blood cells to radiation. radiation that is generated frommedical diagnostic x-ray machines is widely used in medical diagnoses. one of theimportant parameters is kilo-voltage (kv) that is applied across the x-ray tube inmedical diagnostic x-ray machines. kilo-voltage influences the radiation dosage.the aim of this study is to determine the hemolysis, osmotic fragility, andfluorescence anisotropy value on irradiated red blood cells as a function of kvduring medical diagnostic x-ray examinations. materials and methods: the kv,kilo-voltage that is applied across an x-ray tube, of a medical diagnostic x-raymachine was operated at 50, 70 and 100 kv. we determined the hemolysis,osmotic fragility, and fluorescence anisotropy value in red blood cells at 0.5 and 4hours post-irradiation. in order to determine hemolysis and osmotic fragility, therelease of hemoglobin was measured by spectrophotometry technique. 1,6-diphenyl-1,3,5-hexatriene (dph) was used as a molecular probe for determiningfluorescence anisotropy value by fluorescence anisotropy technique. non-irradiatedred blood cells served as the control. results: for the 50, 70, and 100 kv ofmedical diagnostic x-rays, the hemolysis, osmotic fragility, and fluorescenceanisotropy values of irradiated red blood cells at 0.5 and 4 hourspost-irradiation did not significantly change when compared to the control.conclusion: our results suggested that 50, 70, and 100 kv of medical diagnostic x-ray did not influence hemolysis, osmotic fragility, and fluorescence anisotropyvalues of irradiated red blood cells.
|
|
کلیدواژه
|
Medical diagnostic X-ray ,red blood cell ,hemolysis ,osmotic fragility ,fluorescence anisotropy
|
|
آدرس
|
chiang mai university, faculty of associated medical sciences, department of radiologic technology, Thailand, chiang mai university, faculty of associated medical sciences, department of radiologic technology, Thailand, chiang mai university, faculty of associated medical sciences, department of radiologic technology, Thailand, chiang mai university, faculty of associated medical sciences, department of radiologic technology, Thailand
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|