>
Fa   |   Ar   |   En
   Near-Infrared Visual Differentiation in Normal and Abnormal Breast Using Hemoglobin Concentrations  
   
نویسنده mehnati parinaz ,khorram sirous ,zakerhamidi mohammad sadegh ,fahima farhood
منبع journal of lasers in medical sciences - 2018 - دوره : 9 - شماره : 1 - صفحه:50 -57
چکیده    Introduction: near-infrared (nir) optical imaging is a non-ionizing modality that is emerging as a diagnostic/prognostic tool for breast cancer according to nir differentiation of hemoglobin (hb)concentration. methods: the transmission values of led-sourced light at 625 nm were measured by power meter to evaluate the optical properties of hb in breast phantom containing major and minor vessels. for the simulation of blood variations in cancerous breast condition, we prepared 2 concentrations of pre-menopausal hb and 4 concentrations of post-menopausal hb and, for comparison with normal tissue, one concentration of hb injected inside the phantom’s vessels. imaging procedure on the phantom was also conducted by led source and ccd camera. the images from the experiments were compared with the results obtained from the images analyzed by matlab software. finally, mammography of phantom including various concentration of hb was prepared. results: the transmitting intensities of nir in blood containing 1, 2 and 4 concentrations of hb in the major vessels were 52.83 ± 2.85, 43.00 ± 3.11 and 31.17 ± 2.27 μw, respectively, and in minor vessels containing similar hb concentrations were 73.50 ± 2.43, 60.08 ± 5.09 and 42.42 ± 4.86 μw, respectively. the gray-scale levels on the major vessel were about 96, 124, 162 and on the minor vessel about 72, 100, 130 measured for 1, 2 and 4 hb concentrations, respectively. the sensitivity and specificity of nir imaging differentiation were 97.4% and 91.3%, respectively. conclusion: significant differences in transmitting intensity, optical imaging as well as software analysis of images were observed for 1, 2 and 4 concentrations of hb in major and minor breast phantom vessels. differentiation capability of minor vessels was higher than major vessels for hb concentrations. despite a good detection for location of vessels by mammography, it could not show differences between vessels with various concentrations. however, nir optical imaging demonstrated a good image contrast for showing vessels in terms of concentration. this study recommends nir optical imaging for prescreening breast cancer due to its potential for early diagnosis.
کلیدواژه Hemoglobin concentrations; Imaging; Near-infrared; Optical properties
آدرس tabriz university of medical sciences, school of medicine, department of medical physics, Iran, tabriz university, research institute for applied physics and astronomy, Iran, tabriz university, research institute for applied physics and astronomy, Iran, tabriz university of medical sciences, student research committee, Iran
پست الکترونیکی farhood_fahima@yahoo.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved