>
Fa   |   Ar   |   En
   Comparison of Microleakage and Thickness of Resin Cement in Ceramic Inlays with Various Temperatures  
   
نویسنده Alaghemand Homayoun ,Abolghasemzadeh Faezeh ,Pakdel Farzaneh ,Judi Chelan Reza
منبع journal of dental research dental clinics dental prospects - 2014 - دوره : 8 - شماره : 1 - صفحه:45 -50
چکیده    Background and aims. microleakage is still one of the major problems of composite-based restorations. this study compared the microleakage and thickness of resin cement in ceramic inlays with various temperatures. materials and methods. class v cavities were prepared on the buccal and lingual aspects of thirty human molars with occlusal margins in enamel and gingival margins in dentin (3 mm wide, 5 mm long and 2 mm deep). laboratory-made inlays (lmi) were used for buccal cavities, and cad/cam inlays (cmi) were used for lingual cavities. all the cavities were divided into six groups (n=10): 1) lmi at -5°c; 2) lmi at 50°c; 3) lmi at room temperature (25°c); 4) cmi at -5°c; 5) cmi at 50°c; 6) cmi at room temperature (25°c). inlays were bonded to cavities in a pulp pressure- and temperaturesimulating device. after thermocycling and dye penetration, the teeth were divided into two mesiodistal halves. amount of dye penetration and film thickness were measured under a stereomicroscope and analyzed with kruskal-wallis, wilcoxon and spearman's correlation tests (□ = 0.05). results. there were no statistically significant differences in leakage between different inlay temperatures (p > 0.05). the mean cement thickness in laboratory-made inlays (gingival margin, 83.7 ± 11 and occlusal margin, 84.7 ± 19) was greater than that in cad/cam inlays (gingival margin, 69 ± 16 and occlusal margin, 84.7 ± 16). no correlation was found between cement thickness and microleakage either in enamel or dentin for any of the ceramic systems. conclusion. differences in inlay temperature had no effect on microleakage. cad/cam inlays had lower cement thickness than laboratory-made inlays, but this was not related to their microleakage.
کلیدواژه CAD-CAM ,ceramic ,film thickness ,microleakage.
آدرس babol university of medical sciences, Faculty of Dentistry, Dental Material Research Center, Department of Operative Dentistry, ایران, babol university of medical sciences, Faculty of Dentistry, Department of Operative Dentistry, ایران, tabriz university of medical sciences, Faculty of Dentistry, Department of Oral Medicine, ایران, babol university of medical sciences, Faculty of Dentistry, DentalMaterial Research Center, ایران
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved