Fa   |   Ar   |   En
   comparison of the cyclic fatigue resistance of proglider, pathglider and one g path-finding instruments  
   
نویسنده kırıcı damla özsu ,karataş ertuğrul ,uygun ahmet demirhan ,yıldız ezgi doğanay ,çolak kezban meltem ,arslan hakan
منبع journal of dental research dental clinics dental prospects - 2019 - دوره : 13 - شماره : 1 - صفحه:57 -60
چکیده    Background. the aim of the present study was to compare the cyclic fatigue resistance of novel nickel titanium rotary path-finding instruments. methods. twenty instruments were selected for each file system. a simulated stainless steel root canal, with a 90° angle of curvature and a curvature radius of 3 mm, was used for cyclic fatigue test of the proglider (#16, progressive taper: 0.02‒0.085), pathglider (#15, taper: .03), and one g (#14, taper: .03) instruments. statistical analyses were performed with one-way anova (p=0.05). post hoc tukey tests were used to determine any statistically significant differences between the groups. results. the proglider instruments exhibited significantly more cyclic fatigue resistance than both pathglider and one g instruments (p<0.001). one g instruments had significantly more resistance to fracture than pathglider instruments (p<0.05). conclusion. proglider instruments had better cyclic fatigue resistance than pathglider and one g instruments.
کلیدواژه cyclic fatigue ,proglider ,pathglider ,one g
آدرس akdeniz university, faculty of dentistry, department of endodontics, turkey, atatürk university, faculty of dentistry, department of endodontics, turkey, afyon kocatepe university, faculty of dentistry, department of endodontics, turkey, kırıkkale university, faculty of dentistry, department of endodontics, turkey, atatürk university, faculty of dentistry, department of endodontics, turkey, atatürk university, faculty of dentistry, department of endodontics, turkey
پست الکترونیکی dt_hakan82@hotmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved