Fa   |   Ar   |   En
   EMG recording of wrist gestures under non-ideal electrode placement for machine control in a manufacturing environment  
   
نویسنده fu z. ,bani hashim a.y. ,jamaludin z. ,mohamad i.s.
منبع jurnal teknologi - 2015 - دوره : 77 - شماره : 21 - صفحه:41 -49
چکیده    The use of electromyography (emg) for machine control in a manufacturing environment is challenging due to the inherent electrical noise,and also because machine operators lack anatomy knowledge of muscle location for electrode placement. in this research,an electrode placement scheme is proposed for this user group. an emg preamp was constructed to observe emg patterns in lower forearm when electrodes placed by untrained operators are in less optimal locations. crosstalk was found to be a major issue when electrodes are placed in imperfect locations. the emg preamplifier was deliberately constructed with low cost components to simulate the increased floor noise due to electrical interferences f however from the results,the resulting snr is acceptable. this study shows that in designing a practical emg input system,electrode placement is a bigger factor compared to electrical interference. © 2015 penerbit utm press. all rights reserved.
کلیدواژه Biosignal data acquisition; Electromyography; EMG human machine interface; Lower forearm muscles; Manufacturing environment; Synthetic system
آدرس department of robotics and automation, Malaysia, department of robotics and automation, Malaysia, department of robotics and automation, Malaysia, department of thermal fluid,universiti teknikal melaka malaysia,durian tunggal, Malaysia
 
     
   