The Development of Monochromatic Neutron Tomography System at Low Flux Research Reactor
|
|
|
|
|
نویسنده
|
ASHARI NOR ABIDIN ,MOHAMAD SALEH JUNITA ,ABDULLAH MOHD ZAID ,MOHAMAD ABDUL AZIZ ,JAMRO RAFHAYUDI
|
منبع
|
jurnal teknologi - 2008 - دوره : 48 - شماره : D - صفحه:105 -112
|
چکیده
|
A new monochromatic neutron tomography system was built utilizing the malaysia nuclear agency 1mw triga mark ii research reactor located at bangi, selangor. the ccd camera was used in data capturing and the system was evaluated using an experimental phantom made from spark plug. reconstruction was based on the filtered back-projection and the iterative approach. altogether 25 projections were used in the reconstruction and results discussed
|
کلیدواژه
|
Monochromatic ,neutron tomography ,CCD camera ,filtered back–projection ,iterative ,image reconstruction
|
آدرس
|
Universiti Sains Malaysia, Engineering Campus, School of Electrical and Electronic Engineering, Malaysia, Universiti Sains Malaysia, Engineering Campus, School of Electrical and Electronic Engineering, Malaysia, Universiti Sains Malaysia, Engineering Campus, School of Electrical and Electronic Engineering, Malaysia, Malaysian Nuclear Agency, Materials Technology Group of Industrial Technology Division, Malaysia, Malaysian Nuclear Agency, Materials Technology Group of Industrial Technology Division, Malaysia
|