Fa   |   Ar   |   En
   Optimization of the stack in a standing wave thermoacoustic refrigerator at different design temperatures  
   
نویسنده mohd-ghazali n. ,el-fawal m.h.
منبع jurnal teknologi - 2016 - دوره : 78 - شماره : 8-4 - صفحه:127 -132
چکیده    Although numerous successful thermoacoustic refrigerators have been reported to date,the performance of these systems is still lower than their vapor compression counter parts. optimization is imperative to identify the upper limit of the performance in order to be competitive and accepted by the general public. however,optimization methods adopted so far,experimentally and numerically,involved discrete variations of the selected parameters of interest. this paper presents the results of an optimization using the lagrange multiplier method,a mathematical approach never used before. the simultaneous optimization of the stack length and center position at various design temperatures is performed for a standard thermoacoustic refrigerator design. results show similar pattern and trend with previous results with a 24.7% higher stack coefficient of performance achievable. this is promising considering that only two of the design parameters have been optimized. � 2016 penerbit utm press. all rights reserved.
کلیدواژه Lagrange multiplier method; Optimization; Stack center position; Stack length; Thermoacoustic refrigerators
آدرس faculty of mech. engineering,universiti teknologi malaysia utm,johor bahru,johor, Malaysia, faculty of eng. & tech studies,univ. of kordofan,elobied, Sudan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved