|
|
Grip force measurement of soft- Actuated finger exoskeleton
|
|
|
|
|
نویسنده
|
nordin i.n.a.m. ,faudzi a.a.m. ,kamarudin m.z. ,dewi d.e.o. ,rehman t. ,razif m.r.m.
|
منبع
|
jurnal teknologi - 2016 - دوره : 78 - شماره : 6-13 - صفحه:25 -30
|
چکیده
|
Over recent years,the reseach in the field of soft actuation has been extensively increased for achieving more complex motion path with smooth,high flexible movement and high generated force at minimum operating pressure. this paper presents the study on gripping force capability of soft actuators applied on glove-type finger exoskeleton,developed in motivation to assist individuals having weak finger gripping ability in their rehabilitation exercise towards hand function restoration. the exoskeleton utilizes five cylindrical shaped pneumatic bending actuators developed in the lab,which use fiber reinforcement as a cause of bending motion that drive finger’s flexion movement. four right-handed healthy volunteers simulated paralysis participated in the study. at 200kpa safe operating pressure,the soft exoskeleton worn by the subjects demonstrates the ability to provide adequate grip force. the grip force generated from exoskeleton worn on passive right hand is 4.66 ± 0.2 n and 3.61± 0.2 n from passive left hand,both higher than the minimum grip forces measured to hold the hand dynamometer of 240 g. it shows good potential to be used as a finger rehabilitation assist device. © 2016 penerbit utm press. all rights reserved.
|
کلیدواژه
|
Finger exoskeleton; Pneumatic rubber actuator; Soft actuator; Soft robotic glove
|
آدرس
|
control and mechatronics engineering department,faculty of electrical engineering,universiti teknologi malaysia(utm),johor bahru,johor, Malaysia, control and mechatronics engineering department,faculty of electrical engineering,universiti teknologi malaysia(utm),johor bahru,johor,malaysia,center for artificial intelligence and robotics (cairo),universiti teknologi malaysia(utm),johor bahru,johor,malaysia,ijn-utm cardiovascular engineering center,institute of human centred engineering,universiti teknologi malaysia(utm),johor bahru,johor, Malaysia, control and mechatronics engineering department,faculty of electrical engineering,universiti teknologi malaysia(utm),johor bahru,johor, Malaysia, ijn-utm cardiovascular engineering center,institute of human centred engineering,universiti teknologi malaysia(utm),johor bahru,johor,malaysia,department of clinical science,faculty of biosciences and medical engineering,universiti teknologi malaysia(utm),johor bahru,johor, Malaysia, control and mechatronics engineering department,faculty of electrical engineering,universiti teknologi malaysia(utm),johor bahru,johor, Malaysia, control and mechatronics engineering department,faculty of electrical engineering,universiti teknologi malaysia(utm),johor bahru,johor, Malaysia
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|