Internal Jugular Catheter Malposition in a Patient with End Stage Renal Disease: a Case Report
|
|
|
|
|
نویسنده
|
Ebrahimifard Farzaneh ,Shirvani Amir ,Abtahi Shahab ,Setayesh Ali
|
منبع
|
acta medica iranica - 2014 - دوره : 52 - شماره : 9 - صفحه:721 -724
|
چکیده
|
A 30-year-old female with end-stage renal disease was a candidate for dual lumen catheter placement. after catheter insertion, o2 saturation measurement of the aspirated blood from the catheter was similar to that of arterial blood. they referred the patient to our hospital after 48 hours. diagnostic procedures revealed that the tip of the catheter had entered the pleural cavity. catheter removal in the cpr room resulted in hemorrhagic shock. the patient was resuscitated and stabilized and sent to the operating room. a laceration found at the junction of right jugular and right subclavian veins and was surgically repaired. the patient was discharged after ten days without any complication.
|
کلیدواژه
|
Dual-lumen catheter; Malposition; Complications; Internal jugular vein
|
آدرس
|
shahid beheshti university of medical sciences, Faculty of Medicine, Department of General Surgery, ایران, tehran university of medical sciences tums, Faculty of Medicine, Department of General Physician, ایران, tehran university of medical sciences tums, Faculty of Medicine, Department of General Physician, ایران, tehran university of medical sciences tums, Faculty of Medicine, Department of General Surgery, ایران
|
|
|
|
|
|
|
|
|
|
|
|
|
|