   A Study on Ratio of Loss To Storage Modulus For the Blood Clot  
   
نویسنده Soleimani S. ,Pennati G. ,Dubini G.
منبع International Journal Of Engineering - 2014 - دوره : 27 - شماره : 8 - صفحه:1167 -1172
چکیده    In this study, the rheology of blood clot is measured with the help of rotational rheometer. several shear strains (0.5, 1 and 2%) are applied with two frequencies (5 and 10 hz) from the incipient time of clot formation and the response of the sample is measured in the form of shear stress and the phase lag which is interpreted with storage and loss moduli. in this study the ratio of loss to storage modulus is studied and the blood clot gel-point as the transition from viscoelastic fluid to viscoelastic solid is investigated. by increasing the frequency, tan delta decreases before the gel-point and increases after the gel-point which indicates the viscoelastic fluid and viscoelastic solid behaviour,respectively. moreover, by increasing the shear strain, tan delta varies with lower rate at luidic stage (ra1 and ra3) and with higher rate at solid stage (ra2 and ra4). it is also shown that increasing the shear strain causes a delay on gel-point formation.
کلیدواژه Blood Clot; Gel-Point; Loss To Storage Modulus Ratio
آدرس Laboratory Of Biological Structure Mechanics, Department Of Chemistry, Materials And Chemical Engineering Giulio Natta, Italy, Laboratory Of Biological Structure Mechanics, Department Of Chemistry, Materials And Chemical Engineering Giulio Natta, Italy, Laboratory Of Biological Structure Mechanics, Department Of Chemistry, Materials And Chemical Engineering Giulio Natta, Italy
 
     
   