Fa   |   Ar   |   En
   Effect of Wire Pitch on Capacity of Single Staggered Wire and Tube Heat Exchanger Using Computational Fluid Dynamic Simulation  
   
نویسنده Akbar F. R. ,Arsana I. M.
منبع International Journal Of Engineering - 2020 - دوره : 33 - شماره : 8 - صفحه:1637 -1642
چکیده    Single staggered is a design development of normal wire and tube heat exchanger that wires are welded with staggered configuration on two sides. capacity of wire and tube heat exchanger is the ability of the heat exchanger to release heat. the objective of this study is to analyse the effect of wire pitch (pw) on capacity of single staggered wire and tube heat exchanger. the research method uses computational fluid dynamic (cfd) simulation by ansys fluent to analyse heat transfer of wire and tube; also to analyse airflow at surface the wire and tube. the simulation is experimentally validated by measuring temperatures at some points of wire and tube. based on results, temperature contours increasing capacity of heat exchanger depend on smaller wire pitch that the highest value is 72.02 w at pw 7 mm. the reason is smaller wire pitch increases area of convection heat transfer surface. whereas, airflow patterns show air move slowly at the wire and tube surface and flow with free convection. this study contributes new design of wire and tube heat exchanger with cfd and it can be applied to improve the performance of this heat exchanger in refrigeration system and other applications.
کلیدواژه Single Staggered Wire And Tube Heat ,Exchanger ,Heat Transfer ,Natural Convection ,Computational Fluid Dynamic
آدرس Universitas Negeri Surabaya, Department Of Mechanical Engineering, Indonesia, Universitas Negeri Surabaya, Department Of Mechanical Engineering, Indonesia
پست الکترونیکی madearsana@unesa.ac.id
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved