The effect of different Sellick's maneuver on laryngoscopic view and intubation time
|
|
|
|
|
نویسنده
|
JabalameJi M ,Hashemi J ,Mazoochi M
|
منبع
|
journal of research in medical sciences - 2005 - دوره : 10 - شماره : 5 - صفحه:285 -287
|
چکیده
|
Sellick's maneuver (cricoid pressure) may make laryngoscopic view and tracheal intubation more difficult.this study compared the different techniques of cricoid pressure (cp) regarding to the laryngoscopic view andtime to intubation.methods: inl42 anesthetized patients, 4 types of cp was randomly applied; a) one-handed cp using thumb, indexand middle fingers, b) one-handed cp using index and middle fingers, and the heel on the sternum, c) technique a withanother hand below the neck, d) technique c with a pillow below the neck.results: there was significant difference in the laryngoscopic view changes. the view was better in group a, c, dand b, respectively. mean intubation time did, not show significant difference.conctusion: one-handed cp using thumb , i~~middle fingers can provide the best views at laryngoscopy withoutsignificant effect on time to intubation.
|
کلیدواژه
|
Sellick's maneuver ,Laryngoscopic view ,Intubation.time ,Tracheal
|
آدرس
|
isfahan university of medical sciences, Department of Anesthesiology and Intensive care, ایران, isfahan university of medical sciences, Department of Anesthesiology and Intensive care, ایران, isfahan university of medical sciences, ایران
|
پست الکترونیکی
|
jabalameli@med.mui.ac.ir
|
|
|
|
|
|
|
|
|
|
|
|