Fa   |   Ar   |   En
   This study evaluates two different types oftechniques for concrete hollow-block sections reinforced with traditional steel rebars and wire meshes, and compares their structural behaviour to that of an ordinary reinforced concrete beam section. the compa  
   
نویسنده Falah M. Wegian ,T. Alkhamis Mohammad ,Sabbagh Yazdi Saeed Reza
منبع international journal of civil engineering - 2006 - دوره : 4 - شماره : 4 - صفحه:286 -295
چکیده    This study evaluates two different types oftechniques for concrete hollow-block sections reinforced with traditional steel rebars and wire meshes, and compares their structural behaviour to that of an ordinary reinforced concrete beam section. the comparisons are based on the responses both before and after they were repaired with glass fibre reinforced polymers (gfrp). the specimens were subjected to concentrated loading up to initial failure. after failure, the specimens were repaired and loaded once again until ultimate failure. it was shown that the success of the repair by gfrp depended on the mode offailure of the hollow-block concrete beams.
کلیدواژه Masonry ,reinforced ,concrete beam ,hollow-block ,GFRP
آدرس College of Technological Studies (Kuwait), Civil Engineering Department, College of Technological Studies (Kuwait), Civil Engineering Department, k.n.toosi university of technology, Civil Engineering Department, ایران
پست الکترونیکی syazdi@kntu.ac.ir
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center