   The Application of Water Cooling on Reducing NOx from a Gas Burner System  
   
نویسنده Mohd. Jaafar Mohammad Nazri ,Andrews G. E. ,MkPadi M. C.
منبع pertanika journal of science and technology - 2005 - دوره : 13 - شماره : 2 - صفحه:139 -146
چکیده    A gas burner system applying water cooling has been investigated using a 140- mm inside diameter combustor of 294-mm length. the combustor was placed vertically upwards. all tests were conducted using natural gas only. a fixed straight blade radial swirler with 76-mm outlet diameter was placed at the inlet plane of the combustor. an orifice plate of 59 mm was inserted at the exit plane of the swirler to enhance turbulence and help in mixing of the fuel and air. fuel was injected at the back plate of the swirler using central fuel injector with eight fuel holes pointed radially outward. tests were conducted at 5- mmhjo pressure loss. a reduction of about 21.53% on nox emissions was achieved at equivalence ratio of near stoichiometric (0.88) and a reduction of 35.7% was achieved at equivalence ratio of 0.42. other emissions such as carbon monoxide were well under 100 ppm except below the equivalence ratio of 0.5 due to cooling effect. unburned hydrocarbon emissions were well below 10 ppm except below the equivalence ratio of 0.5.
کلیدواژه Oxides of nitrogen ,carbon monoxide ,unburned hydrocarbons ,water cooling
آدرس Universiti Teknologi Malaysia, Mechanical Engineering Faculty, Department of Aeronautics & Automotive, Malaysia, Leeds University, Department of Fuel & Energy, United Kingdom, Leeds University, Department of Fuel & Energy, United Kingdom
 
     
   