   MODEL CORRELATION PROCEDURES FOR AIR-CONDITIONING COPPER DISCHARGE TUBE  
   
نویسنده ZHAO LIM DENG ,FOULADI MOHAMMAD HOSSEINI ,HAW YAP KIM
منبع journal of engineering science and technology - 2014 - دوره : 9 - شماره : Special Issue - صفحه:40 -58
چکیده    Investigations to perform complete finite element (fe) model correlation processes on copper-phosphorus multi-bent tubes in outdoor air-conditioning units were studied. this initiative is part of paparadmy 1’s development plan in validating its fe models for more advanced cae analysis to predict transient and random vibration response analysis. the siemens plm software’s nx software was used to study the modelling, pre-test planning and correlation processes. modal test data on the other hand was obtained from impact hammer tests using bruel & kjaer’s pulse. several industrial metrics to evaluate results from each process were also presented to aid in correlation analysis. both analytical and experimental natural frequencies showed good correlation with percentage error less than 5% for all mode pairs. results from the modal assurance criterion (mac) showed reasonable correlation between experimental and numerical mode shapes with the maximum off-diagonal value being 0.3 and 7 highly correlated mode pairs were obtained. the complete workflows developed from this study is showcased in appendices a, b and c.
کلیدواژه FEA ,Modal Analysis ,Pre-test ,FE Model Correlation ,Copper Tube.
آدرس Taylor’s University, School of Engineering, Malaysia, Taylor’s University, School of Engineering, Malaysia, Panasonic Appliances Air-Conditioning R & D Malaysia Sdn Bhd (PAPARADMY 1), Malaysia
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved