Fa   |   Ar   |   En
   a theoretical detailed analysis for a proposed 5kw pv gridconnected system installed in iraq using pvsyst tool  
   
نویسنده al-khazzar a. a.abbood
منبع iranica journal of energy and environment - 2018 - دوره : 9 - شماره : 2 - صفحه:105 -113
چکیده    In this study, pvsyst simulation software is used to analyze a pv grid tied system in a typical primary school in iraq. the proposed system is 5kw which is affordable and applicable from the cost and required area points respectively. the monthly averaged electrical load for a typical school is approximately calculated. the system simulation has been done for thirteen iraqi provinces while it is described and its performance is analyzed in details for baghdad city as an example. the performance ratio for the system in baghdad is 0.825 and about 9.82mwh is generated by the system per year, 62.7% is consumed by the load and the remaining is injected to the national grid. the results showed that the initial capital cost is $5,442 which is returned after five and a half years. the cost of 1 kwh if the system operates for 10 years is $0.058. this study clearly demonstrates that photovoltaic power system can effectively assist the peak load on the grid. in addition, these systems are very economical/no maintenance project and can be hooked to any the peak time load.
کلیدواژه solar energy ,photovoltaic system ,grid-tied systems ,simulation ,iraq ,pvsyst
آدرس university of baghdad, college of engineering, energy engineering department, iraq
پست الکترونیکی akramabdulameer@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved