چکیده    In this investigation, the application of ceftin drug on prevention of the corrosion of carbon steel in 3 % nacl solution was examined through weight loss (mass loss), gasometric and atomic absorption spectroscopy techniques. the effectiveness of the ceftin drug as corrosion inhibitor for carbon steel was proved by weight losses, gasometric and atomic absorption spectroscopy results. an increase in the ceftin drug concentration decreases the carbon steel weight loss in the 3 % nacl solution, which is due to the formation of invisible thick layer on the carbon steel in the 3 % nacl solution. an increase in the contact time decreases the corrosion inhibition property of expired ceftin drug. gasometric studies showed that, the amount of hydrogen gas evolved decreases with rise in the concentration of 3 % nacl solution. the results of atomic absorption spectroscopy well support the weight loss (mass loss) and gasometric results.
کلیدواژه ceftin drug ,weight loss ,gasometric ,atomic absorption spectroscopy
آدرس k.l.e. society's p. c. jabin science college (autonomous) vidyanagar, department of chemistry, india