Fa   |   Ar   |   En
   Independent component analysis of gait-related movement artifact recorded using EEG electrodes during treadmill walking  
   
نویسنده snyder k.l. ,kline j.e. ,huang h.j. ,ferris d.p.
منبع frontiers in human neuroscience - 2015 - دوره : 9 - شماره : DEC
چکیده    There has been a recent surge in the use of electroencephalography (eeg) as a tool for mobile brain imaging due to its portability and fine time resolution. when eeg is combined with independent component analysis (ica) and source localization techniques,it can model electrocortical activity as arising from temporally independent signals located in spatially distinct cortical areas. however,for mobile tasks,it is not clear how movement artifacts influence ica and source localization. we devised a novel method to collect pure movement artifact data (devoid of any electrophysiological signals) with a 256-channel eeg system. we first blocked true electrocortical activity using a silicone swim cap. over the silicone layer,we placed a simulated scalp with electrical properties similar to real human scalp. we collected eeg movement artifact signals from ten healthy,young subjects wearing this setup as they walked on a treadmill at speeds from 0.4–1.6 m/s. we performed ica and dipole fitting on the eeg movement artifact data to quantify how accurately these methods would identify the artifact signals as non-neural. ica and dipole fitting accurately localized 99% of the independent components in non-neural locations or lacked dipolar characteristics. the remaining 1% of sources had locations within the brain volume and low residual variances,but had topographical maps,power spectra,time courses,and event related spectral perturbations typical of non-neural sources. caution should be exercised when interpreting ica for data that includes semi-periodic artifacts including artifact arising from human walking. alternative methods are needed for the identification and separation of movement artifact in mobile eeg signals,especially methods that can be performed in real time. separating true brain signals from motion artifact could clear the way for eeg brain computer interfaces for assistance during mobile activities,such as walking. © 2015 snyder,kline,huang and ferris.
کلیدواژه Artifact removal; Blind source separation; Cortical sources; Electroencephalography; Walking
آدرس school of kinesiology,university of michigan,ann arbor,mi,united states,department of mathematics and statistics,university of minnesota duluth,duluth,mn, United States, department of biomedical engineering,university of michigan,ann arbor,mi, United States, school of kinesiology,university of michigan,ann arbor,mi, United States, school of kinesiology,university of michigan,ann arbor,mi,united states,department of biomedical engineering,university of michigan,ann arbor,mi, United States
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved