Fa   |   Ar   |   En
   evaluation of the effect of different concentrations of boron on proton therapy of the liver using geant4 monte carlo toolkit  
   
نویسنده tatari m. ,hashemi z. ,naik h.
منبع پژوهش فيزيك ايران - 1401 - دوره : 22 - شماره : 3 - صفحه:153 -159
چکیده    Experimental results have shown that dadding boron to tumor tissue during proton therapy increases the mortality of cancer cells. this work has investigated how to form a spread-out bragg peak in the proton therapy of a liver-located tumor by simulating the mird phantom and designing a range modulator. the simulations were carried out using a geant4 monte carlo toolkit. also, the absorbed dose of the different organs near the liver was determined via simulations. to study the effect of boron on liver proton therapy, a tumor impregnated with different percentages of boron was simulated and the effect of energy released in the tumor as a result of alpha particles, protons and their combinations was investigated. the absorbed dose in the tumor at different proton energies and with varying percentages of boron was investigated. it was found that the absorbed dose in the tumor increases by adding boron, however; it decreases by increasing the energy from a certain limit (~80 mev) of more than 60% boron.
کلیدواژه proton therapy of liver ,bragg peak ,boron ,alpha particles ,geant4 toolkit
آدرس yazd university, faculty of science, physics department, iran, yazd university, faculty of science, physics department, iran, bhabha atomic research centre, radiochemistry division, india
پست الکترونیکی naikhbarc@gmail.com
 
   evaluation of the effect of different concentrations of boron on proton therapy of the liver using geant4 monte carlo toolkit  
   
Authors
Abstract    experimental results have shown that dadding boron to tumor tissue during proton therapy increases the mortality of cancer cells. this work has investigated how to form a spread-out bragg peak in the proton therapy of a liver-located tumor by simulating the mird phantom and designing a range modulator. the simulations were carried out using a geant4 monte carlo toolkit. also, the absorbed dose of the different organs near the liver was determined via simulations. to study the effect of boron on liver proton therapy, a tumor impregnated with different percentages of boron was simulated and the effect of energy released in the tumor as a result of alpha particles, protons and their combinations was investigated. the absorbed dose in the tumor at different proton energies and with varying percentages of boron was investigated. it was found that the absorbed dose in the tumor increases by adding boron, however; it decreases by increasing the energy from a certain limit (~80 mev) of more than 60% boron.
Keywords proton therapy of liver ,bragg peak ,boron ,alpha particles ,geant4 toolkit
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved