   Preliminary characterization tests of detectors of on-line monitor systems of the Italian national center of oncological hadron-therapy (CNAO)  
   
نویسنده ansarinejad a. ,donetti m. ,garella m.a. ,giordanengo s. ,cirio r. ,marchetto f. ,monaco v. ,peroni c. ,sacchi r.
منبع iranian journal of medical physics - 2012 - دوره : 9 - شماره : 4 - صفحه:225 -232
چکیده    Introduction: hadron-therapy is an effective technique used to treat tumors that are located between or nearby vital organs. the italian national center of oncological hadron-therapy (cnao) has been realized as the first facility in italy to treat very difficult tumors with protons and carbon ions. the on-line monitor system for cnao has been developed by the department of physics of the university of torino and italian national institute of nuclear physics (infn). the monitoring system performs the on-line checking of the beam intensity,dimension,and beam position. materials and methods: the monitor system is based on parallel plate ionization chambers and is composed of five ionization chambers with the anodes fully integrated or segmented in pixels or strips that are placed in two boxes. a series of measurements were performed that involve the background current and the detectors have been characterized by means of a series of preliminary testes in order to verify reproducibility and uniformity of the chambers using an x-ray source. results: the measured background currents for stripx,stripy and pixel chambers are five orders of magnitude smaller than the nominal treatment current. the reproducibility error of chambers is less than 1%. the analysis of the uniformity showed that the monitor devices have a spread in gain that varies,but only about 2%. conclusion: the reproducibility and the uniformity values are considered as a good result,taking into account that the xray energy range is several orders of magnitude smaller than the particle energies used at cnao.
کلیدواژه Active beam delivery system; Hadron therapy; Ionization chamber; On-line detectors
آدرس istituto nazionale di fisica nucleare (infn),via giuria 1,torino,italy,dipartimento di fisica sperimentale,universita' di torino,via giuria 1,torino,italy,nuclear science research school,nuclear science and technology research institute, ایتالیا, fondazione cnao,strada campeggi, Italy, fondazione cnao,strada campeggi, Italy, fondazione cnao,strada campeggi, Italy, istituto nazionale di fisica nucleare (infn),via giuria 1,torino,italy,dipartimento di fisica sperimentale,universita' di torino,via giuria 1, Italy, istituto nazionale di fisica nucleare (infn),via giuria 1, Italy, istituto nazionale di fisica nucleare (infn),via giuria 1,torino,italy,dipartimento di fisica sperimentale,universita' di torino,via giuria 1, Italy, dipartimento di fisica sperimentale,universita' di torino,via giuria 1, Italy, istituto nazionale di fisica nucleare (infn),via giuria 1,torino,italy,dipartimento di fisica sperimentale,universita' di torino,via giuria 1, Italy
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved