|
|
|
|
assessment of dose distribution and organ-at-risk exposure in vmat versus 3d-crt for right breast cancer
|
|
|
|
|
|
|
|
نویسنده
|
allah mohamed khairat ,rane atmane ,halimi abdellah ,bouzekraoui youssef ,el ouardy khalid ,hicham asmi
|
|
منبع
|
iranian journal of medical physics - 2026 - دوره : 23 - شماره : 1 - صفحه:18 -25
|
|
چکیده
|
Introduction: breast cancer is one of the most common malignant tumors worldwide, and radiotherapy plays a crucial role in its treatment. this study compares volumetric modulated arc therapy (vmat) and three-dimensional conformal radiotherapy (3d-crt) for right-sided breast cancer treatment, focusing on dosimetric parameters.material and methods: this retrospective study included 20 patients with right breast cancer treated at the international hospital of khouribga (mean age 52.4 ± 4.9 years; mean body mass index (bmi) 27.2 ± 1.1 kg/m²). for each patient, two treatment plans were generated: vmat with dual coplanar arc configuration and 3d-crt with opposed tangential beams. analyzed parameters included target volume coverage and doses to organs at risk. results: vmat provided superior target coverage and dose conformity. the mean homogeneity index (hi) was lower with vmat (0.08 ± 0.02) than 3d-crt (0.14 ± 0.02), and the conformity index (ci) was higher (0.99 ± 0.01 vs. 0.96 ± 0.02). mean heart dose was 4.9 ± 0.7 gray (gy) with vmat versus 1.0 ± 0.2 gy with 3d-crt; ipsilateral lung mean dose was 13.7 ± 1.5 gy versus 11.9 ± 0.7 gy, respectively. contralateral organs received higher low-dose exposure with vmat. vmat achieved improved planning target volume (ptv) coverage and conformity, whereas 3d-crt provided better contralateral organ sparing. conclusion: this study demonstrates vmat's dosimetric advantages over 3d-crt for breast cancer treatment, providing institutional validation for technique selection in resource-limited settings.
|
|
کلیدواژه
|
breast neoplasms radiotherapy ,intensity-modulated radiotherapy conformal radiotherapy dosage planning computer-assisted
|
|
آدرس
|
hassan first university of settat, high institute of health sciences, laboratory of sciences and health technologies, morocco, innovation and sustainable development - multidisciplinary faculty of khouribga, morocco, hassan first university of settat, high institute of health sciences, laboratory of sciences and health technologies, morocco, hassan first university of settat, high institute of health sciences, laboratory of sciences and health technologies, morocco, international clinic of khouribga, radiotherapy department, morocco, high energy physics laboratory, modeling and simulation, morocco
|
|
پست الکترونیکی
|
hichamasmi@gmail.com
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|