Fa   |   Ar   |   En
   detailed ct dosimetry in 4 moroccan hospitals as a preparation for the development of national drls  
   
نویسنده ou-saada imane ,douama sanae ,bouzekraoui youssef ,bosmann hilde ,cockmartin lesley ,campoleoni mauro ,bentayeb farida
منبع iranian journal of medical physics - 2022 - دوره : 19 - شماره : 4 - صفحه:241 -249
چکیده    Introduction: diagnostic reference levels (drls) can prevent excessive, unnecessary radiation exposure to patients and reduce the dose variation during different practices. this study aims to establish local drls for computed tomography (ct) procedures corresponding to head, chest, and abdomen-pelvis examinations (single acquisition) in moroccan hospitals. material and methods: a total of 1917 diagnostic ct examinations were included in this study: head, chest, abdomen–pelvis, lumbar, cervical, chest-abdomen–pelvis (cap), and scanopelvimetry. firstly, we analyzed the ct dose indicators in terms of the volume computed tomography dose index (ctdivol) and the dose length product (dlp) of all the examinations collected. local diagnostic reference levels were proposed just for the head, thorax, and abdomen-pelvis due to the lack of data for the other examinations. furthermore, we calculated the effective dose for chest examination using ct-expo software to estimate the effective and organ dose for chest ct. results: the estimated local drls expressed as the 3^rd quartile using ctdivol were 48 mgy, 14 mgy, and 12 mgy for the head, chest, and abdomen-pelvis, respectively, and 986 mgy.cm, 496 mgy.cm, and 651 mgy.cm for dlp, respectively. moreover, the proposed average effective dose for chest ct examinations was 6,3 msv. conclusion: this work establishes local drls for ctdivol and total dlp for head, chest, and abdomen-pelvis procedures and proposes effective doses for chest ct examinations in adult patients. the study shows that the results are conforming to the literature.
کلیدواژه volume computed ,tomography dose index (ctdivol) ,dose length product (dlp) ,diagnostic reference ,levels (drls) ,head ,chest ,abdomen-pelvis
آدرس university mohammed v, faculty of sciences, laboratory of high energy physics modelisation simulation, morocco, university mohammed v, faculty of sciences, laboratory of high energy physics modelisation simulation, morocco, hassan first university of settat, high institute of health sciences, laboratory of sciences and health technologies, morocco, katholieke universiteit leuven, faculty of medicine, department of imaging and pathology, belgium, universitair ziekenhuis leuven, department of radiology, belgium, associazione italiana di fisica medica (aifm), italy, university mohammed v, faculty of sciences, laboratory of high energy physics modelisation simulation, morocco
پست الکترونیکی bentayebfr@yahoo.fr
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved