|
|
|
|
dosimetric comparison between dynamic wave arc and co-planar volumetric modulated radiotherapy for locally advanced pancreatic cancer
|
|
|
|
|
|
|
|
نویسنده
|
abdelghaffar alshaymaa ,kishi noriko ,ashida ryo ,matsuo yukinori ,hirashima hideaki ,mukumoto nobutaka ,yoshimura michio ,nakamura mitsuhiro ,mohamed ahmed el sayed ,ali elsayed mostafa ,gaber mohamed soliman ,mizowaki takashi
|
|
منبع
|
iranian journal of medical physics - 2022 - دوره : 19 - شماره : 1 - صفحه:1 -8
|
|
چکیده
|
Introduction: dose reduction to the duodenum is important to decrease gastrointestinal toxicities in patients with locally advanced pancreatic cancer (lapc) treated with definitive chemoradiotherapy. we aimed to compare dynamic wave arc (dwa), a volumetric-modulated beam delivery technique with simultaneous gantry/ring rotations passing the waved trajectories, with coplanar vmat (co-vmat) with respect to dose distributions in lapc cases. material and methods: dwa and co-vmat plans were created for 13 patients with lapc. the prescribed dose was 45.6 or 48 gy in 15 fractions. the dose volume indices (dvis) for target volumes and organs at risk were compared between the corresponding plans. gamma passing rate, monitor unit (mu), and beam-on time were also compared. results: dwa significantly reduced the duodenal v39gy, v42gy, and v45gy by 1.1, 0.8, and 0.2 cm^3, and increased the liver mean dose and d2cm3 of the spinal cord planning volume by 1.0 and 1.5 gy, respectively. meanwhile, there was no significant difference in the target volumes except for d2% of ptv (111.5% in dwa vs. 110.5% in co-vmat). further, the gamma passing rate was similar in both plans. mu and beam-on time increased in dwa by 31 mus and 15 seconds, respectively. conclusion: dwa generated significantly lower duodenal doses in lapc cases, albeit with slight increasing liver and spinal cord doses and increasing mu and the beam delivery time. further evaluation is needed to know how the dose differences would affect the clinical outcomes in chemoradiotherapy for lapc.
|
|
کلیدواژه
|
radiotherapy planning computer ,assisted pancreas cancer volumetric modulated arc therapy
|
|
آدرس
|
kyoto university, graduate school of medicine, department of radiation oncology and image-applied therapy, japan. sohag university, sohag university hospital, department of clinical oncology, egypt, kyoto university, graduate school of medicine, department of radiation oncology and image-applied therapy, japan, kyoto university, graduate school of medicine, department of radiation oncology and image-applied therapy, japan. kobe city medical center general hospital, department of radiation oncology, japan, kyoto university, graduate school of medicine, department of radiation oncology and image-applied therapy, japan, kyoto university, graduate school of medicine, department of radiation oncology and image-applied therapy, japan, kyoto university, graduate school of medicine, department of radiation oncology and image-applied therapy, japan, kyoto university, graduate school of medicine, department of radiation oncology and image-applied therapy, japan, kyoto university, graduate school of medicine, department of information technology and medical engineering, department of radiation oncology and image-applied therapy, japan, sohag university, sohag university hospital, department of clinical oncology, egypt, sohag university, sohag university hospital, department of clinical oncology, egypt, sohag university, sohag university hospital, department of clinical oncology, egypt, kyoto university, graduate school of medicine, department of radiation oncology and image-applied therapy, japan
|
|
پست الکترونیکی
|
mizo@kuhp.kyoto-u.ac.jp
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|