>
Fa   |   Ar   |   En
   investigation of noise level and spatial resolution of ct images filtered with a selective mean filter and its comparison to an adaptive statistical iterative reconstruction  
   
نویسنده zahro ummu mar'atu ,anam choirul ,budi wahyu setia ,triadyaksa pandji ,saragih jhon hadearon ,rukmana dito andi
منبع iranian journal of medical physics - 2021 - دوره : 18 - شماره : 5 - صفحه:376 -383
چکیده    Introduction: a simple noise reduction algorithm, i.e. a selective mean filter (smf), had been previously introduced. the aim of this study is to investigate the image qualities filtered by a smf and its comparison to an adaptive statistical iterative reconstruction (asir). material and methods: to assess the basic image quality, an american association of physicists in medicine computed tomography (aapm ct) performance phantom was used. the phantom was scanned by 128 multiple slices computed tomography. the tube current varied from 50 ma to 100, 150, and 200 ma. the images of a phantom were reconstructed by filtered back projection (fbp) followed by smf and asir (20, 40, 60, 80, and 100%). the image quality assessment was in terms of noise level, noise power spectrum (nps), and modulation transfer function (mtf). results: the noise level and nps of smf was similar with asir 100%. the values of the mtf10 of the asir filter at any level and smf were comparable. the mtf10 values of asir 60%, and smf with 50 ma (low) were 0.76 ± 0.02 and 0.75 ± 0.02 cycle/mm, respectively. meanwhile, the mtf10 of asir 60% and smf with 200 ma (high) were 0.74 ± 0.00 and 0.73 ± 0.00 cycles/mm, respectively. conclusion: our results indicated that the performance of the smf in reducing noise is equivalent to the maximum level of asir strength, i.e., asir 100%.
کلیدواژه computed tomography ,image quality ,algorithms ,image processing ,selective mean filter ,adaptive statistical ,iterative reconstruction
آدرس diponegoro university, faculty of sciences and mathematics, department of physics, indonesia, diponegoro university, faculty of sciences and mathematics, department of physics, indonesia, diponegoro university, faculty of sciences and mathematics, department of physics, indonesia, diponegoro university, faculty of sciences and mathematics, department of physics, indonesia, diponegoro university, faculty of sciences and mathematics, department of physics, indonesia, indriati hospital solo baru, department of radiology, indonesia
پست الکترونیکی dito.rukmana@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved