Introduction: this study aimed to report the measurement of photon and electron beams to configure the analytical anisotropic algorithm and electron monte carlo used in clinical treatment. material and methods: all measurements were performed in a large water phantom using a 3-dimensional scanning system (ptw, germany). for photon beams, the data were measured with a 0.125cc cylindrical chamber. for electron, the data were performed with a roos chamber. results: in photon beams, flatness and symmetry for reference field size 10×10cm² were within the tolerance intervals. flatness were 0.79% and 1.55% for x6mv and x18mv, respectively. symmetry were 0.57 and 0.25 for x6mv and x18mv, respectively. the output factor vary between 0.83 and 1.11 for x6mv. moreover, it varies between 0.74 and 1.09 for x18mv. the leaf transmission factors were 0.97% for x6mv and1.14% for x18mv. the dlg were 1.31 and 1.34 for x6mv and x18mv, respectively. for electron beams, the quality index r50 for applicator 15×15cm² were in the tolerance. maximum depth dose for 6, 9, 12, 16 and 20mev were 1.2, 1.9, 2.7, 2.99 and 2.4cm, respectively. bremsstrahlung tail were 6mev–2.86cm, 9mev–4.32cm, 12mev–5.96cm, 16mev–7.93cm, and 20mev–10.08cm per energy levels. conclusion: the obtained results and international recommendations were in a good agrement.
|
کلیدواژه
|
linear accelerator algorithm ,monte carlo method ,radiotherapy
|
آدرس
|
mohamed v university, faculty of sciences, physics department, morocco. sheikh khalifa ibn zaid hospital, department of radiotherapy, morocco, mohamed v university, faculty of sciences, physics department, morocco, hassan 1st university, higher institute of health sciences, laboratory of research in health sciences and technologies, morocco, sheikh khalifa ibn zaid hospital, department of radiotherapy, morocco. mohamed v university, faculty of sciences, physics department, morocco, mohamed v university, faculty of sciences, physics department, morocco, mohamed v university, faculty of sciences, physics department, morocco, mohamed v university, faculty of sciences, physics department, morocco
|
پست الکترونیکی
|
benkhouyassine@gmail.com
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|