Fa   |   Ar   |   En
   calculation of inter- and intra-fraction motion errors at external radiotherapy using a markerless strategy based on image registration combined with correlation model  
   
نویسنده parandeh sohelia ,esmaili torshabi ahmad ,samadi miandoab payam
منبع iranian journal of medical physics - 2019 - دوره : 16 - شماره : 3 - صفحه:224 -231
چکیده    Introduction: a new method based on image registration technique and an intelligent correlation model to calculate. the present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional patient positioning methods. material and methods: the configuration of the markerless method was accomplished by using four-dimensional computed tomography (4dct) datasets. firstly, the mevislab software package was used to extract a three-dimensional (3d) surface model of the patient and determine the tumor location. then, the patient-specific 3d surface model which also included the breathing phases was imported into the matlab software package in order to define several control points on the thorax region as virtual external markers. finally, based on the correlation of breathing signals/patient position with breathing signals/tumor coordinate, an adaptive neuro fuzzy inference system was proposed to both verify and align the inter- and intra-fraction motion errors in radiotherapy, if needed. in order to validate the proposed method, the 4dct data acquired from four real patients was considered.results: final results revealed that our hybrid configuration method was capable of aligning patient setup with lower uncertainties, compared to other available methods. in addition, the 3d root-mean-square error has been reduced from 5.26 to 1.5 mm for all patients. conclusion: in this study, a markerless method based on the image registration technique in combination with a correlation model was proposed to address the limitations of the available methods, including dependence on operator’s attention, use of passive markers, and rigid-only constraint for patient setup.
کلیدواژه image processing ,image guided radiation therapy (igrt) ,patient positioning
آدرس graduate university of advanced technology, department of electrical and computer engineering, medical radiation group, iran, graduate university of advanced technology, department of electrical and computer engineering, medical radiation group, iran, amirkabir university of technology, faculty of energy engineering and physics, iran
پست الکترونیکی p.samadi1989@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved