   development of computed tomography head and body phantom for organ dosimetry  
   
نویسنده omojola akintayo daniel ,oluwafemi ajibade ,kehinde ololade ,adeneye samuel olaolu ,nusirat adedewe ,aderonke adedokun ,aweda moses adebayo ,aboyewa oluyemi bright ,akpochafor michael onoriode
منبع iranian journal of medical physics - 2019 - دوره : 16 - شماره : 1 - صفحه:8 -14
چکیده    Introduction: quality assurance in computed tomography (ct) centers in developing countries are largely hindered by the unavailability of ct phantoms. the development of a local ct phantom for the measurement of organ radiation absorbed dose is therefore requisite. material and methods: local ct phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for head, and 14 cm in length respectively. the outer plastic shell was made using poly (methyl methacrylate [pmma]) sheet. the developed ct phantoms were validated against a standard phantom. radiation absorbed dose was determined by scanning the setup with the same protocol used for the standard phantom. the local phantoms were then verified for organ radiation absorbed dose measurement using bovine tissues. the set up was ct-scanned, and hounsfield units (hu) for bovine tissues were obtained. results: there was no significant difference between the local and standard head phantoms (p=0.060). similarly, no difference was noted between the local and standard body phantoms (p=0.795). the percentage difference in volume ct dose index (ctdivol) between the body (local and standard) phantoms was higher than that for the head phantoms. there were no significant differences in hu between bovine and human brain, liver, kidney and lung tissues (p=0.938). conclusion: the local phantoms showed good agreement with the standard ones. the developed phantoms can be used for ct organ radiation absorbed dose measurement in radiology departments in nigeria.
کلیدواژه phantom ,organ ,radiation dosage ,computed tomography ,thermoluminescent dosimetry
آدرس federal medical centre asaba, department of radiology, medical physics unit, nigeria, faculty of medicine, lagos teaching hospital, department of radiation biology, radiotherapy, radiodiagnosis and radiography, nigeria, faculty of medicine, lagos teaching hospital, department of radiation biology, radiotherapy, radiodiagnosis and radiography, nigeria, faculty of medicine, lagos teaching hospital, department of radiation biology, radiotherapy, radiodiagnosis and radiography, nigeria, faculty of medicine, lagos teaching hospital, department of radiation biology, radiotherapy, radiodiagnosis and radiography, nigeria, faculty of medicine, lagos teaching hospital, department of radiation biology, radiotherapy, radiodiagnosis and radiography, nigeria, faculty of medicine, lagos teaching hospital, department of radiation biology, radiotherapy, radiodiagnosis and radiography, nigeria, federal university of technology, department of physics, nigeria, faculty of medicine, lagos teaching hospital, department of radiation biology, radiotherapy, radiodiagnosis and radiography, nigeria
پست الکترونیکی akpochafor@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved