Fa   |   Ar   |   En
   a validation study on radiation properties of a novel lif: mg, ti known as iap-100  
   
نویسنده mohammadi kheirollah ,gholamhosseinian najjar hamid ,baziar omid ,mohammadi aghil ,bayani roodi shahram
منبع iranian journal of medical physics - 2018 - دوره : 15 - شماره : 2 - صفحه:117 -125
چکیده    Introduction: lif dosimeter has the most application in medicine. this study aimed to evaluate some dosimetric properties of a novel lif: mg, ti. materials and methods: an elekta precise linear accelerator was used to calibrate dosimeters at 6 mv. in this survey, responses of dosimeters were evaluated up to 1000 cgy. background effect was investigated in two different dosimeter states including irradiated and unirradiated.thermoluminescence response dependence to dose rate was investigated, as well. energy dependence was evaluated in diagnostic and therapeutic ranges. furthermore, fading effect was evaluated by reading the dosimeters every 2 h up to 12 h postirradiation.  results: the dosimeters had linear response up to 250 cgy. readout values of dosimeters receiving 120 cgy at three dose rates of 21, 212, 425 cgy.min^-1 were calculated equal to 125, 123, 121 cgy, respectively. the measured values of delivering 80, 120, and 150 cgy prescribed doses at 6 mv, 10 mv, and 15 mv were accurate at 6 mv and about 1.5 times higher than the prescribed doses at 10 and 15 mv. thermoluminescence response in diagnostic energy range showed an uprising trend with increasing energy. conclusion: the raising thermoluminescence response with increasing energy contradicts with the findings of nunn. due to the reproducibility and linear response of dosimeters in an acceptable dose range, they could be used in diagnostic and therapeutic fields. effects of absorbed doses from background in lowdose studies, mainly in diagnostic radiology range, could be evaluated in more detail in future surveys.
کلیدواژه radiation dosimeters ,reproducibility of results ,reading ,calibration
آدرس malekashtar university, iran, mashhad university of medical sciences, faculty of medicine, department of medical physics, iran, mashhad university of medical sciences, faculty of medicine, department of medical physics, iran, amirkabir university of technology, faculty of energy engineering and physics, iran, mashhad university of medical sciences, faculty of medicine, department of medical physics, iran
پست الکترونیکی bayanirsh1@mums.ac.ir
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved