Fa   |   Ar   |   En
   بررسی هوادهی بین دریچه در بازشدگی همزمان دریچه سرویس و اضطراری و ارائه روابط برای عملکرد توام دریچه ها  
   
نویسنده حسنیان شیروان ساناز ,محمد علی نژادیان دامون ,کاویانپور محمد رضا
منبع هيدروليك - 1401 - دوره : 17 - شماره : 2 - صفحه:47 -56
چکیده    در ﻣﻘﺎﻟﻪ ﺣﺎﺿﺮ ﺑﺎ اﺳﺘﻔﺎده از ﻣﺪل آزﻣﺎﯾﺸﮕﺎﻫﯽ ﺗﺨﻠﯿﻪ ﮐﻨﻨﺪه ﺗﺤﺘﺎﻧﯽ ﺳﺪ ﺳﯿﺎزاخ، ﮐﻪ در ﻣﻮﺳﺴﻪ ﺗﺤﻘﯿﻘﺎت آب ﻣﻮﺟﻮد اﺳﺖ، ﺑﻪ ﺑﺮرﺳﯽ ﻋﻤﻠﮑﺮد ﺗﻮام دو درﯾﭽﻪ ﺳﺮوﯾﺲ و اﺿﻄﺮاری، ﭘﺮداﺧﺘﻪ ﺷﺪ. ﭼﻨﯿﻦ ﺷﺮاﯾﻄﯽ وﻗﺘﯽ ﮐﻪ درﯾﭽﻪ ﺳﺮوﯾﺲ ﺧﺮاب اﺳﺖ و درﯾﭽﻪ اﺿﻄﺮاری وارد ﻋﻤﻞ ﻣﯽﺷﻮد، رخ ﻣﯽ دﻫﺪ. آزﻣﺎﯾﺶﻫﺎ ﺑﻪ ازای 4 ﺑﺎر آﺑﯽ ﻣﺨﺰن و 6 ﺑﺎزﺷﺪﮔﯽ ﻣﺨﺘﻠﻒ درﯾﭽﻪﻫﺎ از 10% ﺗﺎ 80% اﻧﺠﺎم ﺷﺪ. ﻓﺸﺎر ﺑﺮ روی ﺑﺪﻧﻪ ﻣﺠﺮای ﺗﺨﻠﯿﻪ ﮐﻨﻨﺪه ﻗﺮاﺋﺖ ﺷﺪ و دﺑﯽ ﻋﺒﻮری از ﻟﻮﻟﻪ ﻫﻮاده ﺑﯿﻦ دو درﯾﭽﻪ ﺗﻮﺳﻂ ﺳﯿﻢ داغ اﻧﺪازه ﮔﯿﺮی ﺷﺪ. ﻧﺘﺎﯾﺞ ﻧﺸﺎن داد ﮐﻪ زﻣﺎﻧﯽ ﮐﻪ درﯾﭽﻪ ﺳﺮوﯾﺲ در ﯾﮏ ﺑﺎزﺷﺪﮔﯽ ﻣﺸﺨﺺ ﺧﺮاب ﺷﺪه و درﯾﭽﻪ اﺿﻄﺮاری وارد ﻣﺪار ﻣﯽﺷﻮد، ﺑﯿﺸﺘﺮﯾﻦ ﻣﯿﺮان ﺗﻘﺎﺿﺎی ﻫﻮا رخ ﻣﯽدﻫﺪ و ﻣﻘﺪار ﺑﺎزﺷﺪﮔﯽ درﯾﭽﻪ اﺿﻄﺮاری ﺑﺎ درﯾﭽﻪ ﺳﺮوﯾﺲ ﺑﺮاﺑﺮ ﺷﺪه ﯾﺎ ﮐﻤﺘﺮ از آن ﻣﯽﺷﻮد. ﺑﺎ اﻧﺪازهﮔﯿﺮی ﻣﻘﺪار ﻫﻮای ورودی از ﻟﻮﻟﻪ ﻫﻮاده در 24 ﺣﺎﻟﺖ ﻣﺨﺘﻠﻒ آزﻣﺎﯾﺸﮕﺎﻫﯽ و ﻣﻘﺎﯾﺴﻪ آنﻫﺎ ﺑﺎ ﭘﺎراﻣﺘﺮﻫﺎی ﻣﺨﺘﻠﻒ، راﺑﻄﻪای ﺑﺮای ﺗﻌﯿﯿﻦ ﺿﺮﯾﺐ ﻫﻮادﻫﯽ اراﺋﻪ ﮔﺮدﯾﺪ ﮐﻪ ﺗﺎﺑﻊ ﻋﺪد ﻓﺮود اﺳﺖ و ﻣﺤﺪوده ای ﺑﯿﻦ ﺣﺪ ﺑﺎﻻ و ﭘﺎﯾﯿﻦ ﻋﺪد ﻓﺮود داده ﻫﺎ را ﺷﺎﻣﻞ ﻣﯽﺷﻮد.
کلیدواژه پدیده کاویتاسیون، دریچه تخلیه، ضریب هوادهی، میدان جریان، دریچه اضطراری
آدرس دانشگاه سیستان و بلوچستان, ایران, دانشگاه شیراز, ایران, دانشگاه صنعتی خواجه نصیرالدین طوسی, ایران
پست الکترونیکی kavianpour@kntu.ac.ir
 
   Study of Aeration Between Valves in Opening of Service and Emergency Valves and Providing Relationships for Joint Operation of Valves  
   
Authors Hasanian Shirvan Sanaz ,Mohamad Ali Nezhadian Damoon ,Kavianpoor Mohamadreza
Abstract    IntroductionDrain valves are usually constructed to control and drain flood, regulate flow, drain tank in critical cases, discharge sediment, and transfer current. Therefore, the study of their hydraulic conditions during design and operation should be considered by researchers and designers. As the height of the dam increases, the flow velocity in the semiopen valves of the dam also increases and as a result, the local pressure decreases, which consequently causes the cavitation phenomenon The presence of air near the rigid boundaries of the flow greatly reduces the destructive effect of cavitation and therefore the method of aeration and its effects and the percentage of air bubbles in the vicinity of these boundaries to prevent cavitation is one of the points to know the different types of aeration mechanism and bubble placement, and the type of valve according to the flow conditions. As mentioned, one of the phenomena that can endanger the safety of valves is cavitation. In these valves, the twophase flow of air is transmitted at high speed. Due to the separation of the flow lines, a sharp drop in the downstream values of the valve occurs.MethodologySiazakh rock dam is located in a place called Siazakh and at the junction of two tributaries of Ghezelozen river named Kaqli and Sheikh Haidar, 7 km from Divandere. The level of the dam on the riverbed is 1756 meters above sea level. The purpose of constructing this dam is to supply agricultural water, control and control river floods. In the middle of the duct, the control system is located, consists of an emergency sliding valve and a sliding service valve. The physical model of the valve includes a repair valve, a metal cover with a rectangular cross section, a duct inlet, a valve groove, a middle duct, an emergency valve, an emergency valve chamber, its grooves, a service valve, a vent between two valves and the entire downstream duct. In order to provide the required water height and required discharge, an open metal tank has been used. This tank is in the form of a cylinder with a diameter of 5 meters and a height of 6 meters.In order to measure the pressures on the valve, 8 piezometers are installed on the valve and all these piezometers are connected to the tightly connected hoses. The experiments were performed for four different heads. Two pumps and an outlet adjustment valve were used to adjust the head, so that only one pump was switched on at the lower heads and the output valve was bypassed to adjust the head. This time was chosen according to the turbulence of the air flow and minimizing its error by trial and error.Results and discussionAfter adjusting the head, the service valve was placed in the preplanned openings and the emergency valve was displaced so much that the most critical situation occurred. The criterion for detecting this critical state is the velocity of air suction from the aeration pipe between the two valves into the duct, which was measured by a hot wire. To measure the air velocity, the hot wire is placed inside the aeration tube in the center of the tube for one minute. After the desired time, the average inlet air velocity is recorded by the hot wire device. The results show that the most critical situation occurs when the jet passing under the emergency valve hits exactly the lower edge of the service valve. In this case, a severe disturbance occurs between the empty space of the two valves, which causes severe suction of air into the aeration pipe. According to observational experience, this condition is usually achieved when the percentage of emergency valve opening is up to about 5% less than the service valve opening.ConclusionThe results of this study showed that when the emergency valve is broken in a certain opening and consequently the emergency valve enters the circuit, the most critical situation is when the amount of emergency valve opening is equal to the service valve. By measuring the amount of incoming air from the aeration tube in 24 different laboratory modes, and comparing them with different parameters, a relation was provided to determine the aeration coefficient which is a function of the landing number and includes a range between the lower and upper limits of the data. Also, by examining the amount of inlet air flow from the aeration tube for 24 different experiments, it was observed that this amount of air has a relative maximum at two points, the first maximum being related to low openings.
Keywords
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved