|
|
determination of osteoblast cell viability and histological changes of samples obtained from different implant drills during osteotomy
|
|
|
|
|
نویسنده
|
moradi haghgoo janet ,khoshhal masoumeh ,sharifi shahram ,khodadadi iraj ,ghadidmi pour hamidreza ,seif rabie mohammad ali ,rabienejad nazli
|
منبع
|
journal of dentistry, shiraz university of medical sciences - 2023 - دوره : 24 - شماره : 2 - صفحه:220 -225
|
چکیده
|
Statement of the problem: the bone particles collected during osteotomy could be used as autogenous bone graft materials for dental implant surgery. different factors such as drill design may influence its clinical viability. purpose: this study examined the effect of drill design on the osteoblast viability and his-topathology parameters of bone collected during the preparation of dental implant site. materials and method: in this experimental study, 90 samples were obtained from three different bone drilling systems including bego, implantium, and dio during fixture installa-tion in patients requiring treatment at the department of periodontology, dentistry universi-ty hamedan. the mtt (3-4,5-dimethylthiazol2,5-diphenyltetrazolium bromide) was used to determine percentage of cell viability. samples were fixed in 10% formaldehyde for hist-ological evaluation. then, they were kept in 10% edta solution for 4 weeks for decalcific-ation. the provided slides were evaluated regarding bone structure and osteocytes counts for assessment of viability. tukey test and spps 21 software were used for statistical analysis. results: the result showed the viability of osteoblast obtained by dio (0.45±0.04) was significantly better than bego (0.37±0.05) and implantium (0.37±0.04) systems. in histo-pathological evaluation, the grafting material obtained by dio presented the best osteoblast morphology. conclusion: it might be concluded that drill geometry has significantly influenced the via-bility of bone particles collected during the preparation of implant sites .moreover, charac-teristic geometry alone cannot represent the performance of a particular drill, and several geometric features should be concerned. the results of this study showed that the geometry of the dio drill was the best considering the viability and histopathological evaluations.
|
کلیدواژه
|
bone grafting; particle size; dental implant; cell viability; osteotomy
|
آدرس
|
hamadan university of medical sciences, school of dentistry, department of periodontics, iran, , iran, , iran, hamadan university of medical sciences, school of medicine, department of biochemistry, iran, hamadan university of medical sciences, department of pathology, iran, hamadan university of medical sciences, school of medicine, department of sociable medicine, iran, hamadan university of medical sciences, school of dentistry, department of periodontics, iran
|
پست الکترونیکی
|
nazlirabi@yahoo.com
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|