Fa   |   Ar   |   En
   A Comparison of Themarginal and Internal Fit of Cobalt- Chromium Copings Fabricated By Two Different Cad/Camsystems (Cad/ Milling, Cad/ Ceramill Sintron)  
   
نویسنده Vojdani Mahroo ,Torabi Kianoosh ,Atashkar Berivan ,Heidari Hossein ,Torabi Ardakani Mahshid
منبع Journal Of Dentistry, Shiraz University Of Medical Sciences - 2016 - دوره : 17 - شماره : 4 - صفحه:301 -308
چکیده    Statement of the problem: marginal fitness is the most important criteria for evaluation of the clinical acceptability of a cast restoration. marginal gap which is due to cement solubility and plaque retention is potentially detrimental to both tooth and periodontal tissues. purpose: this in vitro study aimed to evaluate the marginal and internal fit of cobaltchromium (co-cr) copings fabricated by two different cad/cam systems: (cad/ milling and cad/ ceramill sintron). materials and method: we prepared one machined standard stainless steel master model with following dimensions: 7 mm height, 5mm diameter, 90˚ shoulder marginal finish line with 1 mm width, 10˚ convergence angle and anti-rotational surface on the buccal aspect of the die. there were 10 copings produced from hard presintered co-cr blocks according to cad/ milling technique and ten copings from soft non- presintered co-cr blocks according to cad/ ceramill sintron technique. marginal and internal accuracies of copings were documented by the replica technique. replicas were examined at ten reference points under a digital microscope (230x). the student's ttest was used for statistical analysis. p< 0.001 was considered significant. results: statistically significant differences existed between the groups (p< 0.001). the cad/milling group (hard copings) had a mean marginal discrepancy (md) of 104 μm, axial discrepancy (ad) of 23 μm and occlusal discrepancy of 130 μm. for cad/ ceramill sintron group, these values were 195 μm (md), 46 μm (ad), and 232 μm (od). internal total discrepancy (itd) for the cad/milling group was 77 μm, whereas for the cad/ceramill sintron group was 143 μm. conclusion: hard presintered co-cr copings had significantly higher marginal and internal accuracies compared to the soft non-presintered copings.
کلیدواژه Marginal And Internal Fit; Cad/Cam; Ceramill Sintron; Base Metal Alloy
آدرس Shiraz University Of Medical Sciences, School Of Dentistry, Dept. Of Prosthodontics, ایران, Shiraz University Of Medical Sciences, School Of Dentistry, Dept. Of Prosthodontics, ایران, Shiraz University Of Medical Sciences, School Of Dentistry, ایران, Azad University Of Medical Sciences, School Of Dentistry, Dept. Of Prosthodontics, ایران
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved